Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
During the past two decades, the focus has been on the need to provide communities with structures that undergo minimal damage after an earthquake event while still being cost competitive. This has led to the development of high performance seismic resisting systems, and advances in design methodologies, in order respect this demand efficiently. This paper presents the experimental response of four pre-cast, post-tensioned rocking wall systems tested on the shake-table at the University of Canterbury. The wall systems were designed as a retrofit solution for an existing frame building, but are equally applicable for use in new design. Design of the wall followed a performance-based retrofit strategy in which structural limit states appropriate to both the post-tensioned wall and the existing building were considered. Dissipation for each of the four post-tensioned walls was provided via externally mounted devices, located in parallel to post-tensioned tendons for re-centring. This allowed the dissipation devices to be easily replaced or inspected following a major earthquake. Each wall was installed with viscous fluid dampers, tension-compression yielding steel dampers, a combination of both or no devices at all – thus relying on contact damping alone. The effectiveness of both velocity and displacement dependant dissipation are investigated for protection against far-field and velocity-pulse ground motion characteristics. The experimental results validate the behaviour of ‘Advanced Flag-Shape’ rocking, dissipating solutions which have been recently proposed and numerically tested. Maximum displacements and material strains were well controlled and within acceptable bounds, and residual deformations were minimal due to the re-centring contribution from the post tensioned tendons. Damage was confined to inelastic yielding (or fluid damping) of the external dampers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures
Holmes, W. T. (2000) · Earthquake Spectra · doi:10.1193/1.1586085 · Cited by 1,164
Displacement-based seismic design of structures
Calvi, G. M., & Kowalsky, M. J. (2007) · Cited by 1,076
Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building
Priestley, M. J. N., Sritharan, S. (., Conley, J. R., & Stefano Pampanin, S. (1999) · PCI Journal · doi:10.15554/pcij.11011999.42.67 · Cited by 873 · cited 4×
“As part of Phase III of the United States PRESSS program (PREcast Seismic Structural Systems (Priestley et al. 1999)), a 60% scale prototype building was constructed and tested (Pseudo-dynamic testing) comprising of a precast posttensioned coupled wall system orthogonal to a hybrid moment resisting…”
BackgroundMethod
Cited by
Marriott, D., Pampanin, S., & Palermo, A. (2009) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.857 · Cited by 383
Self-citationSelf‐centering structural systems with combination of hysteretic and viscous energy dissipations
Kam, W. Y., Pampanin, S., Palermo, A., & Carr, A. J. (2010) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.983 · Cited by 178
“[43, 44] have performed shaking-table test on BLEV and AFS1 systems on structural walls as shown in Figure 7(c).”
MethodSelf-citationExperimental Testing of Rocking Cross-Laminated Timber Walls with Resilient Slip Friction Joints
Hashemi, A., Zarnani, P., Masoudnia, R., & Quenneville, P. (2018) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001931 · Cited by 169
Metadata
- Authors
- Marriott, D., Pampanin, S., Bull, D., & Palermo, A.
- Venue
- Bulletin of the New Zealand Society for Earthquake Engineering
- Published
- 2008-06-30
- Volume
- 41
- Issue
- 2
- Pages
- 90-103
- ISSN
- 0110-0718 (ISSN-L)
- 2324-1543
- 1174-9857
- OpenAlex
- W1906689320
- Cited by
- 187
- References
- 3
- FWCI
- 13.49
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.