Cited by 46Obstructive Sleep Apnea ResearchRespiratory Support and MechanismsSleep and related disorders

All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices

Open access
Zhu, Kaixian, Roisman, Gabriel, Aouf, Sami, Escourrou, Pierre·2015·Journal of Clinical Sleep Medicine

Abstract

Study objectives This study challenged on a bench-test the efficacy of auto-titrating positive airway pressure (APAP) devices for obstructive sleep disordered breathing treatment and evaluated the accuracy of the device reports.Methods Our bench consisted of an active lung simulator and a Starling resistor. Eleven commercially available APAP devices were evaluated on their reactions to single-type SDB sequences (obstructive apnea and hypopnea, central apnea, and snoring), and to a long general breathing scenario (5.75 h) simulating various SDB during four sleep cycles and to a short scenario (95 min) simulating one sleep cycle.Results In the single-type sequence of 30-minute repetitive obstructive apneas, only 5 devices normalized the airflow (> 70% of baseline breathing amplitude). Similarly, normalized breathing was recorded with 8 devices only for a 20-min obstructive hypopnea sequence. Five devices increased the pressure in response to snoring. Only 4 devices maintained a constant minimum pressure when subjected to repeated central apneas with an open upper airway. In the long general breathing scenario, the pressure responses and the treatment efficacy differed among devices: only 5 devices obtained a residual obstructive AHI < 5/h. During the short general breathing scenario, only 2 devices reached the same treatment efficacy (p < 0.001), and 3 devices underestimated the AHI by > 10% (p < 0.001). The long scenario led to more consistent device reports.Conclusion Large differences between APAP devices in the treatment efficacy and the accuracy of report were evidenced in the current study.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5664/jcsm.4844

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 38 · Cited by 46

Authors
Zhu, K., Roisman, G., Aouf, S., & Escourrou, P.
Affiliations
  • Université Paris-Sud (FR)
  • Assistance Publique – Hôpitaux de Paris (FR)
  • Air Liquide (France) (FR)
Corresponding author
Zhu, Kaixian
Venue
Journal of Clinical Sleep Medicine
Published
2015-07-15
Volume
11
Issue
7
Pages
725-734
ISSN
  • 1550-9389 (ISSN-L)
  • 1550-9397
OpenAlex
W2396847105
Cited by
46
References
38
Citations by year
2026: 5 · 2025: 5 · 2024: 4 · 2023: 4 · 2022: 8 · 2020: 2 · 2019: 6 · 2018: 1 · 2017: 5 · 2016: 3 · 2015: 3
FWCI
2.95
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Sleep Medicine (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
CPAP devices, obstructive sleep apnea, sleep-disordered breathing, lung simulator, apnea-hypopnea index, central sleep apnea, snoring, treatment efficacy
MeSH terms
Automation, Equipment Design, Equipment Safety, Humans, Positive-Pressure Respiration, Sleep Apnea Syndromes, Reproducibility of Results, Equipment Failure Analysis, Benchmarking, Sleep Apnea, Obstructive, Sleep Apnea, Central

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review