Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 416

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Normative EMG Values during REM Sleep for the Diagnosis of REM Sleep Behavior Disorder

Open access
Frauscher, Birgit, Iranzo, Alex, Gaig, Carles, Gschliesser, Viola, Guaita, Marc, Raffelseder, Verena, Ehrmann, Laura, Sola, Nuria, Salamero, Manel, Tolosa, Eduardo, Poewe, Werner, Santamaria, Joan, Högl, Birgit·2012·Sleep

Abstract

BACKGROUND: Correct diagnosis of rapid eye movement sleep behavior disorder (RBD) is important because it can be the first manifestation of a neurodegenerative disease, it may lead to serious injury, and it is a well-treatable disorder. We evaluated the electromyographic (EMG) activity in the Sleep Innsbruck Barcelona (SINBAR) montage (mentalis, flexor digitorum superficialis, extensor digitorum brevis) and other muscles to obtain normative values for the correct diagnosis of RBD for clinical practice. SETTING: Two university hospital sleep disorder centers. PARTICIPANTS: Thirty RBD patients (15 idiopathic [iRBD], 15 with Parkinson disease [PD]) and 30 matched controls recruited from patients with effectively treated sleep related breathing disorders. INTERVENTIONS: Not applicable. METHODS AND RESULTS: Participants underwent video-polysomnography, including registration of 11 body muscles. Tonic, phasic, and "any" (any type of EMG activity, irrespective of whether it consisted of tonic, phasic or a combination of both) EMG activity was blindly quantified for each muscle. When choosing a specificity of 100%, the 3-sec miniepoch cutoff for a diagnosis of RBD was 18% for "any" EMG activity in the mentalis muscle (area under the curve [AUC] 0.990). Discriminative power was higher in upper limb (100% specificity, AUC 0.987-9.997) than in lower limb muscles (100% specificity, AUC 0.813-0.852). The combination of "any" EMG activity in the mentalis muscle with both phasic flexor digitorum superficialis muscles yielded a cutoff of 32% (AUC 0.998) for patients with iRBD and with PD-RBD. CONCLUSION: For the diagnosis of iRBD and RBD associated with PD, we recommend a polysomnographic montage quantifying "any" (any type of EMG activity, irrespective of whether it consisted of tonic, phasic or a combination of both) EMG activity in the mentalis muscle and phasic EMG activity in the right and left flexor digitorum superficialis muscles in the upper limbs with a cutoff of 32%, when using 3-sec miniepochs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.1886

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 416

Metadata

Authors
Frauscher, B., Iranzo, A., Gaig, C., Gschliesser, V., Guaita, M., Raffelseder, V., Ehrmann, L., Sola, N., Salamero, M., Tolosa, E., Poewe, W., Santamaria, J., & Högl, B.
Venue
Sleep
Published
2012-06
Volume
35
Issue
6
Pages
835-847
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2072449729
Cited by
416
References
29
FWCI
14.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normative EMG Values during REM Sleep for the Diagnosis of REM Sleep Behavior Disorder. https://app.cochat.ai/papers/10.5665/sleep.1886
The paper
Frauscher, B., Iranzo, A., Gaig, C., Gschliesser, V., Guaita, M., Raffelseder, V., Ehrmann, L., Sola, N., Salamero, M., Tolosa, E., Poewe, W., Santamaria, J., & Högl, B. (2012). Normative EMG Values during REM Sleep for the Diagnosis of REM Sleep Behavior Disorder. Sleep. https://doi.org/10.5665/sleep.1886

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.