The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Agreement in the Scoring of Respiratory Events and Sleep Among International Sleep Centers
Open accessAbstract
STUDY OBJECTIVES: The American Academy of Sleep Medicine (AASM) guidelines for polysomnography (PSG) scoring are increasingly being adopted worldwide, but the agreement among international centers in scoring respiratory events and sleep stages using these guidelines is unknown. We sought to determine the interrater agreement of PSG scoring among international sleep centers. DESIGN: Prospective study of interrater agreement of PSG scoring. SETTING: Nine center-members of the Sleep Apnea Genetics International Consortium (SAGIC). MEASUREMENTS AND RESULTS: Fifteen previously recorded deidentified PSGs, in European Data Format, were scored by an experienced technologist at each site after they were imported into the locally used analysis software. Each 30-sec epoch was manually scored for sleep stage, arousals, apneas, and hypopneas using the AASM recommended criteria. The computer-derived oxygen desaturation index (ODI) was also recorded. The primary outcome for analysis was the intraclass correlation coefficient (ICC) of the apnea-hypopnea index (AHI). The ICCs of the respiratory variables were: AHI = 0.95 (95% confidence interval: 0.91-0.98), total apneas = 0.77 (0.56-0.87), total hypopneas = 0.80 (0.66-0.91), and ODI = 0.97 (0.93-0.99). The kappa statistics for sleep stages were: wake = 0.78 (0.77-0.79), nonrapid eye movement = 0.77 (0.76-0.78), N1 = 0.31 (0.30-0.32), N2 = 0.60 (0.59-0.61), N3 = 0.67 (0.65-0.69), and rapid eye movement = 0.78 (0.77-0.79). The ICC of the arousal index was 0.68 (0.50-0.85). CONCLUSION: There is strong agreement in the scoring of respiratory events among the SAGIC centers. There is also substantial epoch-by-epoch agreement in scoring sleep variables. Our results suggest that centralized scoring of PSGs may not be necessary in future research collaboration among international sites where experienced, well-trained scorers are involved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Obstructive Sleep Apnea as a Risk Factor for Stroke and Death
Yaggi, H. K., Concato, J., Kernan, W. N., Lichtman, J. H., Brass, L. M., & Mohsenin, V. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043104 · Cited by 3,004
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
Cited by
Global burden of sleep‐disordered breathing and its implications
Lyons, M. M., Bhatt, N. Y., Pack, A. I., & Magalang, U. J. (2020) · Respirology · doi:10.1111/resp.13838 · Cited by 422
Self-citationInternational Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationMiller, D. J., Sargent, C., & Roach, G. D. (2022) · Sensors · doi:10.3390/s22166317 · Cited by 328
“…the agreement relative to PSG. PSG scoring is performed manually by trained technicians, and there is often variability across technicians scoring identical records—the level of chance ‐ corrected agreement between technicians is sub ‐ stantial rather than almost perfect ( κ = 0.78) [20].”
InfluentialExpert-level sleep scoring with deep neural networks
Biswal, S., Sun, H., Goparaju, B., Westover, M. B., Sun, J., & Bianchi, M. T. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy131 · Cited by 290
Obstructive sleep apnoea in the general population: highly prevalent but minimal symptoms
Arnardottir, E. S., Bjornsdottir, E., Olafsdottir, K. A., Benediktsdottir, B., & Gislason, T. (2016) · European Respiratory Journal · doi:10.1183/13993003.01148-2015 · Cited by 261
Metadata
- Authors
- Magalang, U. J., Chen, N.-H., Cistulli, P. A., Fedson, A. C., Gíslason, T., Hillman, D., Penzel, T., Tamisier, R., Tufik, S., Phillips, G., Pack, A. I., & for the SAGIC Investigators
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-04-01
- Volume
- 36
- Issue
- 4
- Pages
- 591-596
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2032299679
- Cited by
- 166
- References
- 4
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Agreement in the Scoring of Respiratory Events and Sleep Among International Sleep Centers. https://app.cochat.ai/papers/10.5665/sleep.2552
- The paper
- Magalang, U. J., Chen, N.-H., Cistulli, P. A., Fedson, A. C., Gíslason, T., Hillman, D., Penzel, T., Tamisier, R., Tufik, S., Phillips, G., Pack, A. I., & for the SAGIC Investigators. (2013). Agreement in the Scoring of Respiratory Events and Sleep Among International Sleep Centers. Sleep. https://doi.org/10.5665/sleep.2552
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.