Cited by 198Environmental Impact and SustainabilityClinical Laboratory Practices and Quality ControlHealthcare cost, quality, practices

The carbon footprint of pathology testing

Open access
McAlister, Scott, Barratt, Alexandra L, Bell, Katy JL, McGain, Forbes·2020·Medical Journal of Australia

Abstract

Objectives To estimate the carbon footprint of five common hospital pathology tests: full blood examination; urea and electrolyte levels; coagulation profile; C-reactive protein concentration; and arterial blood gases. Design, setting Prospective life cycle assessment of five pathology tests in two university-affiliated health services in Melbourne. We included all consumables and associated waste for venepuncture and laboratory analyses, and electricity and water use for laboratory analyses. Main outcome measure Greenhouse gas footprint, measured in carbon dioxide equivalent (CO2e) emissions. Results CO2e emissions for haematology tests were 82 g/test (95% CI, 73–91 g/test) for coagulation profile and 116 g/test (95% CI, 101–135 g/test) for full blood examination. CO2e emissions for biochemical tests were 0.5 g/test CO2e (95% CI, 0.4–0.6 g/test) for C-reactive protein (low because typically ordered with urea and electrolyte assessment), 49 g/test (95% CI, 45–53 g/test) for arterial blood gas assessment, and 99 g/test (95% CI, 84–113 g/test) for urea and electrolyte assessment. Most CO2e emissions were associated with sample collection (range, 60% for full blood examination to 95% for coagulation profile); emissions attributable to laboratory reagents and power use were much smaller. Conclusion The carbon footprint of common pathology tests was dominated by those of sample collection and phlebotomy. Although the carbon footprints were small, millions of tests are performed each year in Australia, and reducing unnecessary testing will be the most effective approach to reducing the carbon footprint of pathology. Together with the detrimental health and economic effects of unnecessary testing, our environmental findings should further motivate clinicians to test wisely.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5694/mja2.50583

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The carbon emissions of one complete STR profile are comparable to those generated by a full blood examination in a hospital setting.

    “However, a rough theoretical LCA suggests that one complete STR profile contributes roughly 0.1 kg carbon dioxide equivalent (CO2e) (Table 4), comparable to the carbon emissions generated by a full blood examination in a hospital setting [150].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 20

  1. Landrigan PJ, Fuller R, Acosta NJR, et al. The Lancet Commission on pollution and health. Lancet 2018; 391: 462-512.
  2. Eckelman MJ, Sherman J. Environmental impacts of the US health care system and effects on public health. PLoS One 2016; 11: e0157014.
  3. Malik A, Lenzen M, McAlister S, McGain F. The carbon footprint of Australian health care. Lancet Planet Health 2018; 2: 27-35.
  4. Pichler PP, Jaccard IS, Weisz U, Weisz H. International comparison of health care carbon footprints. Environ Res Lett 2019; 14: 064004.
  5. Zhi M, Ding EL, Theisen-Toupal J, et al. The landscape of inappropriate laboratory testing: a 15-year meta- analysis. PLoS One 2013; 8: e78962.
  6. Cassel CK, Guest JA. Choosing wisely: helping physicians and patients make smart decisions about their care. JAMA 2012; 307: 1801-1802.
  7. Sherman JD, MacNeill A, Thiel C. Reducing pollution from the health care industry. JAMA 2019; 322: 1043-1044.
  8. International Organization for Standardization. ISO 14040:2006. Environmental management. Life cycle assessment: principles and framework. 2nd edition. Geneva: ISO, 2006.
  9. Sherman J, Le C, Lamers V, Eckelman M. Life cycle greenhouse gas emissions of anesthetic drugs. Anesth Analg 2012; 114: 1086-1090.
  10. McAlister S, Ou Y, Neff E, et al. The environmental footprint of morphine: a life cycle assessment from opium poppy farming to the packaged drug. BMJ Open 2016; 6: e013302.
  11. Eckelman M, Mosher M, Gonzalez A, Sherman J. Comparative life cycle assessment of disposable and reusable laryngeal mask airways. Anesth Analg 2012; 114: 1067-1072.
  12. Haines A, Ebi K. the imperative for climate action to protect health. N Engl J Med 2019; 380: 263-273.
  13. Wernet G, Bauer C, Steubing B, et al. The ecoinvent database version 3 (part I): overview and methodology. Int J Life Cycle Assess 2016; 21: 1218-1230.
  14. Ciroth A, Muller S, Weidema B, Lesage P. Empirically based uncertainty factors for the pedigree matrix in ecoinvent. Int J Life Cycle Assess 2016; 21: 1338-1348.
  15. Wernet G, Conradt S, Isenring HP, et al. Life cycle assessment of fine chemical production: a case study of pharmaceutical synthesis Int J Life Cycle Assess 2010; 15: 294-303.
  16. Bell KJL, Doust J, Glasziou P, et al. Recognizing the potential for overdiagnosis: are high-sensitivity cardiac troponin assays an example? Ann Intern Med 2019; 170: 259.
  17. Bjørn Morten H. Too much technology. BMJ 2015; 350: h705.
  18. Spelman D. Inappropriate pathology ordering and pathology stewardship. Med J Aust 2015; 202: 13-15. https://www.mja.com.au/journal/2015/202/1/inappropriate-pathology-ordering-and-pathology-stewardship 28
  19. Pathirana T, Clark J, Moynihan R. Mapping the drivers of overdiagnosis to potential solutions. BMJ 2017; 358: j3879.
  20. Rao GG, Crook M, Tillyer ML. Pathology test: is the time for demand management ripe at last? J Clin Pathol 2003; 56: 243-248

Cited by

Authors
McAlister, S., Barratt, A. L., Bell, K. J., & McGain, F.
Affiliations
  • The University of Melbourne (AU)
  • The University of Sydney (AU)
Corresponding author
McAlister, Scott
Venue
Medical Journal of Australia
Publisher
Wiley
Published
2020-04-18
Volume
212
Issue
8
Pages
377-382
ISSN
  • 0025-729X (ISSN-L)
  • 1326-5377
OpenAlex
W3016965265
Cited by
198
References
1
Citations by year
2026: 36 · 2025: 48 · 2024: 41 · 2023: 24 · 2022: 20 · 2021: 20 · 2020: 9
FWCI
6.55
Type
journal article
Language
en
Open access
Locations
  • The Medical Journal of Australia (publishedVersion)
  • PubMed (publishedVersion)
  • Minerva Access (University of Melbourne) (submittedVersion)
  • The Sydney eScholarship Repository (The University of Sydney) (submittedVersion)
Funders
  • Department of Health, State Government of Victoria
  • National Health and Medical Research Council (1104136)
Topics
  • Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Health Professions › General Health Professions › Healthcare cost, quality, practices
Keywords
carbon footprint, greenhouse gas emissions, life cycle assessment, venipuncture, phlebotomy, sample collection, coagulation parameters, C-reactive protein, arterial blood gases, laboratory reagents, power consumption, water consumption, unnecessary testing, environmental impact of healthcare
MeSH terms
Australia, Humans, Pathology, Specimen Handling, Phlebotomy, Carbon Footprint

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review