Cited by 1

Preuse/Poststerilization Integrity Testing (PUPSIT): To Do or Not to Do?

Gupta, Vivek Sheel, Jindal, Jitendra, Gupta, Ashawant, Gupta, Nalini Kant·2020·PDA Journal of Pharmaceutical Science and Technology

Abstract

In manufacture of heat labile sterile drug products, the final step involves filtration through sterilizing grade filters. It is the drug manufacturer's responsibility to check whether an integral filter has been used. One method used widely to check the integrity of a filter is the bubble point test. To confirm that the filter used is integral, the postuse integrity test is made obligatory by regulatory bodies. However, preuse/poststerilization integrity testing (PUPSIT) of filters remains debatable for the risks associated in its execution. Although PUPSIT is recommended by regulatory bodies, it poses a risk of compromising downstream sterility and involves high costs to mitigate such risks. This study highlights the impact of filter clogging on bubble point values with the consequent possibility of a nonintegral filter passing postuse integrity testing. The results clearly show an increase in postuse bubble point values, which can camouflage a possible flaw in sterilizing filters. The fluid streams 20% dextrose, 0.001% bentonite, paclitaxel, and 0.05% sodium hyaluronate were selected based not only on the commonality of their clogging propensity but also on the different nature of streams that influence the clogging of sterilizing filters. Paclitaxel is an injectable for oncotherapy, and 0.05% sodium hyaluronate is an ophthalmic. The study was conducted with 0.2 μm sterilizing filters from four different manufacturers. It was observed that some fluid streams show a signifi…

Integrity signals

Registry

Crossref · 10.5731/pdajpst.2018.009449

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In many cases, including in some recent studies pertaining to filter integrity testing, a bubble point test is the only test used to assess the integrity of a filter.

    “However, in many cases, including in some recent studies pertaining to filter integrity testing, a bubble point test is the only test used to assess the integrity of a filter [20,21].”

Cited by

Authors
Gupta, V. S., Jindal, J., Gupta, A., & Gupta, N. K.
Venue
PDA Journal of Pharmaceutical Science and Technology
Published
2019-11-15
Volume
74
Issue
3
Pages
301-308
ISSN
  • 1079-7440
  • 1948-2124
Cited by
1
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›