Laboratory Critical Values Policies and Procedures
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Context.—Critical values lists have been used for many years to decide when to notify physicians and other caregivers of potentially life-threatening situations; however, these lists have not been studied widely. Objectives.—To investigate critical values lists in institutions participating in the College of American Pathologists Q-Probes program and to provide suggestions for improvement. Setting.—A total of 623 institutions voluntarily participating in the Q-Probes program. Design.—A multipart study in which participants responded to information from preprinted lists, collected information about current practices, completed a questionnaire, monitored critical values calls, reviewed patients' medical records, and surveyed nursing supervisors and physicians about critical values. Main Outcome Measures.—Defining critical values systems, including lists, personnel, costs, processes, usefulness, and related medical outcomes. Results.—Critical values lists were determined for routine chemistry and hematology analytes and were found to vary widely among participants. In contrast, more than 95% of participants reported positive blood cultures, cerebrospinal fluid cultures, and toxic therapeutic drug levels as critical values. Based on more than 13 000 critical values, participants' data showed that most critical values reports (92.8%) were made by the person who performed the test, and that 65% of reports for inpatients were received by nurses. For outpatients, physicians' office staff received the largest percentage (40%) of reports. The majority of participants (71.4%) had no policy on how repeat critical calls should be handled. On average, completion of notification required about 6 minutes for inpatients and 14 minutes for outpatients. Slightly greater than 5% of critical value telephone calls were abandoned, with the largest percentage abandoned for outpatients. More than 45% of critical values were unexpected, and 65% resulted in a change in therapy. Although only 20.8% of 2301 nursing supervisors thought critical values lists were helpful, 94.9% of 514 physicians found critical values lists valuable. Conclusions.—Critical values systems were medically important, highly variable, but also costly practices for participants. We propose a number of recommendations for improvement, including that the critical values list should be approved by the medical staff, each laboratory should develop a written policy for handling initial and repeat critical values reports, a foolproof policy should be established to report results from calls abandoned, and efforts at automating the process should become widespread.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laboratory Results: Timeliness as a Quality Attribute and Strategy
Howanitz, J. H., & Howanitz, P. J. (2001) · American Journal of Clinical Pathology · doi:10.1309/h0dy-6vtw-nb36-u3l6 · Cited by 108
Self-citationCritical (Panic) Value Notification: An Established Laboratory Practice Policy (Parameter)
Lundberg, G. D. (1990) · JAMA · doi:10.1001/jama.1990.03440050103044 · Cited by 103
Critical Limits for Urgent Clinician Notification at US Medical Centers
Kost, G. J. (1990) · JAMA · doi:10.1001/jama.1990.03440050098042 · Cited by 94
Quality assurance measurements in departments of pathology and laboratory medicine.
Howanitz, P. J. (1990) · PubMed · Cited by 82
Self-citationDecision support alerts for clinical laboratory and blood gas data
Shabot, M. M., LoBue, M., Leyerle, B. J., & Dubin, S. B. (1990) · International journal of clinical monitoring and computing · doi:10.1007/bf02915529 · Cited by 39
Laboratory-Related Measures of Patient Outcomes: An Introduction
Bissell, M. G. (2000) · Cited by 15
Managing the Patient-Focused Laboratory
Benson, E. S. (1977) · JAMA · doi:10.1001/jama.1977.03270280071032 · Cited by 11
Diuretic Therapy, Hypertension, and Cardiac Arrest
Bigger, J. T. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406303302613 · Cited by 11
Decision Support Alerts for Clinical Laboratory and Blood Gas Data
Shabot, M. M., LoBue, M., Leyerle, B. J., & Dubin, S. B. (1994) · Computers and medicine · doi:10.1007/978-1-4612-2698-7_11 · Cited by 3
Cited by
Taylor, R. A., Pare, J. R., Venkatesh, A. K., Mowafi, H., Melnick, E. R., Fleischman, W., & Hall, M. K. (2016) · Academic Emergency Medicine · doi:10.1111/acem.12876 · Cited by 491
Fumbled handoffs: one dropped ball after another
Gandhi, T. K. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-5-200503010-00010 · Cited by 246
Managing the Pre- and Post-analytical Phases of the Total Testing Process
Hawkins, R. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.1.5 · Cited by 244
Errors in Laboratory Medicine: Practical Lessons to Improve Patient Safety
Howanitz, P. J. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-1252-eilmpl · Cited by 218
Self-citation
Metadata
- Authors
- Howanitz, P. J., Steindel, S. J., & Heard, N. V.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2002-06-01
- Volume
- 126
- Issue
- 6
- Pages
- 663-669
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2121743808
- Cited by
- 173
- References
- 9
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.