Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; the references it cites are not checked yet.

Implementation of a Point-of-Care Satellite Laboratory in the Emergency Department of an Academic Medical Center: Impact on Test Turnaround Time and Patient Emergency Department Length of Stay

Abstract

Context. —Emergency department (ED) overcrowding has reached crisis proportions in the United States. Many hospitals are seeking to identify process reengineering efforts to reduce crowding and ED patient length of stay (LOS). Objectives. —To investigate the impact of a point-of-care testing (POCT) satellite laboratory in the ED of a large academic medical center. Setting. —The ED of the Massachusetts General Hospital, Boston, Mass. Design and Outcome Measures. —Evaluation of physician satisfaction, turnaround time (TAT), and ED LOS before and after implementation of a POCT laboratory. ED LOS was measured by patient chart audits. TAT was assessed by manual and computer audits. Clinician satisfaction surveys measured satisfaction with test TAT and test accuracy. Results. —Blood glucose, urine human chorionic gonadotropin, urine dipstick, creatine kinase–MB, and troponin tests were performed in the ED POCT laboratory. Test TAT declined an average of 87% after the institution of POCT. The ED LOS decreased for patients who received pregnancy testing, urine dipstick, and cardiac markers. Although these differences were not significant for individual tests, when the tests were combined, the decreased LOS was, on average, 41.3 minutes ( P = .006). Clinician satisfaction surveys documented equivalent satisfaction with test accuracy between the central laboratory and the POCT laboratory. These surveys also documented dissatisfaction with central laboratory TAT and increased satisfaction with TAT of the POCT program ( P < .001). Conclusions. —The POCT satellite laboratory decreased test TAT and decreased ED LOS. There was excellent satisfaction with test accuracy and TAT.

Overview

Integrity signals

Registry

Crossref · 10.5858/2003-127-0456-ioapsl

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

References 8 · Cited by 202

Research works printed but not linked: 2

  1. Landro, L. Emergency rooms hope new technology will ease their trauma. Wall Street Journal July 13, 2001:B1.
  2. Landro, L. Emergency rooms hope new technology will ease their trauma. Wall Street Journal July 13, 2001:B1.

Metadata

Authors
Lee-Lewandrowski, E., Corboy, D., Lewandrowski, K., Sinclair, J., McDermot, S., & Benzer, T. I.
Affiliations
Harvard University (US)
Corresponding author
Benzer, Theodore I.
Venue
Archives of Pathology & Laboratory Medicine
Published
2003-04
Volume
127
Issue
4
Pages
456-460
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W2213123163
Cited by
202
References
8
Citations by year
2026: 3 · 2025: 3 · 2024: 4 · 2023: 6 · 2022: 11 · 2021: 6 · 2020: 10 · 2019: 7 · 2018: 8 · 2017: 6 · 2016: 5 · 2015: 7 · 2014: 9 · 2013: 8 · 2012: 8
FWCI
5.75
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Pathology & Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Emergency Medicine › Emergency and Acute Care Studies
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
Keywords
point-of-care testing, satellite laboratory, emergency department overcrowding, emergency department length of stay, turnaround time, physician satisfaction, central laboratory, cardiac biomarkers, pregnancy testing, urine dipstick, blood glucose, troponin, creatine kinase-MB, human chorionic gonadotropin
MeSH terms
Academic Medical Centers, Emergency Medical Services, Female, Humans, Laboratories, Hospital, Length of Stay, Male, Massachusetts, Middle Aged, Quality Assurance, Health Care, Time Factors, Clinical Laboratory Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implementation of a Point-of-Care Satellite Laboratory in the Emergency Department of an Academic Medical Center: Impact on Test Turnaround Time and Patient Emergency Department Length of Stay. https://app.cochat.ai/papers/10.5858/2003-127-0456-ioapsl
The paper
Lee-Lewandrowski, E., Corboy, D., Lewandrowski, K., Sinclair, J., McDermot, S., & Benzer, T. I. (2003). Implementation of a Point-of-Care Satellite Laboratory in the Emergency Department of an Academic Medical Center: Impact on Test Turnaround Time and Patient Emergency Department Length of Stay. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2003-127-0456-ioapsl

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.