Steroid Profiles Using Liquid Chromatography–Tandem Mass Spectrometry With Atmospheric Pressure Photoionization Source
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Immunoassays are among the most sensitive and precise analytical methods. However, recent studies1–14 have shown that many immunoassays lack specificity owing to cross-reactivity. Furthermore, results from the College of American Pathologists Proficiency Testing Program (CAP PT Program) for the year 2002 (Y-Survey)14 clearly showed that the antibodies used in the commercially available immunoassays lack specificity. Table 1 presents the mean low and mean high values for each steroid using the different immunoassays currently available, and the data strongly illustrate their lack of specificity. In the past, steroids were analyzed individually using gas chromatography–mass spectrometry (MS) or immunoassay. Gas chromatography–MS is both sensitive and specific, but requires tedious and time-consuming sample preparation. Liquid chromatography–MS (LC-MS) and liquid chromatography–tandem MS are specific and offer simpler approaches to sample preparation without sample derivatization steps. Recently, a number of LC-MS–based methods using different ion sources have been reported for the determination of the following steroid hormones: testosterone,15–17 cortisol,18–22 11-deoxycortisol,23 androstenedione,1617 dehydroepiandrosterone (DHEA),24 dehydroepiandrosterone 3-sulfate (DHEAS),1624 progesterone,25 17-hydroxyprogesterone,26 estriol,27 and estradiol.1627Prior to the advent of the atmospheric pressure photoionization (APPI) ion source,28 the LC-MS–based methods mentioned above used either an atmospheric pressure chemical ionization (APCI) or electrospray ionization source. Without multistep sample preparation procedures, the APCI source usually cannot provide adequate sensitivity for some steroids, such as estradiol and DHEA in human serum. The electrospray ionization source is considered more sensitive than the APCI source for polar compounds. However, for the nonpolar or low-polar compounds, such as most steroid molecules, the sensitivity provided by the electrospray ionization source is less satisfactory2225 than the APCI source. The more recently introduced APPI source has been demonstrated to be significantly more sensitive than APCI for certain compounds.28 Alary29 used APPI–tandem MS for the detection of steroids in biological matrices, and reported that in both selected ion monitoring mode and multiple reaction monitoring (MRM) mode, the signal obtained by photoionization was more intense by a factor of 3 to 10 when compared to the APCI source.Because of the high sensitivity provided by the APPI source for steroids, we hypothesized that stable isotope dilution tandem MS in the MRM mode would allow for the rapid simultaneous quantitation of numerous steroids in a single sample. This article describes a method that permits the simultaneous measurement of 9 steroids in a 760-μL sample of serum or plasma, without derivatization and with minimal sample workup—acetonitrile protein precipitation. The reliability of the method has been evaluated by correlation with currently used immunoassays, and assessment of within-day and between-day imprecision, recovery, and accuracy. Comparison of results obtained by tandem MS with the all method mean (CAP PT Program, 2002)14 has also been performed.Androstenedione (4-androstene-3,17-dione), testosterone (4-androsten-17β-ol-3-one), DHEA (5-androsten-3β-ol-17-one), DHEAS (5-androsten-3β-ol-17-one sulfate, sodium salt), cortisol (4-pregnen-11β,17α,21-triol-3,20-dione), 11-deoxycortisol (4-pregnen-17α,21-diol-3,20-dione), progesterone (4-pregnen-3,20-dione), 17α-hydroxyprogesterone (4-pregnen-17α-ol-3,20-dione), 17β-estradiol (1,3,5[10]-estratriene-3,17β-diol), estriol (1,3,5[10]-estratriene-3,16α,17β-triol), ammonium acetate, and bovine albumin (96%) were purchased from Sigma-Aldrich (St Louis, Mo). Deuterium-labeled internal standards (testosterone-1,2-d2, cortisol-9,11,12,12-d4, and estradiol-2,4,16,16-d4) were from Cambridge Isotope Laboratory, Inc (Andover, Mass); 4-androstene-3,17-dione-2,2,4,6,6,16,6-d7, dehydroepiandrosterone-16,16-d2, 4-pregnen-17α-ol-3,20-dione-2,2,4,6,6,21,21,21-d8, 11-deoxycortisol-21,21-d2, estriol-2,4-d2, and progesterone-2,2,4,6,6,17α,21,21,21-d9 were from C/D/N Isotopes Inc (Pointe-Claire, Quebec). High-performance liquid chromatography–grade water and methanol were obtained from Burdick & Jackson (Muskegon, Mich). Optima-grade acetonitrile and toluene were from Fisher Scientific (Fair Lawn, NJ). All chemicals (except those noted otherwise) had a purity of at least 98%, as reported by the manufacturer.Stock solutions of 1.0 mg/mL in methanol were prepared for each steroid of interest and stored at −20°C. Working profile standard solutions at various concentrations were prepared as follows: appropriate amounts of the stock solutions were mixed and diluted with methanol to obtain a solution containing 7.81 μg/mL of 11-deoxycortisol, 2.96 μg/mL of 17α-hydroxyprogesterone, 1.26 μg/mL of androstenedione, 0.344 μg/mL of estradiol, 2.73 μg/mL of DHEA,
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isobe, T., Shiraishi, H., Yasuda, M., Shinoda, A., Suzuki, H., & Morita, M. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01851-4 · Cited by 228
Cited by
Konkle, A. T. M., & McCarthy, M. M. (2011) · Endocrinology · doi:10.1210/en.2010-0607 · Cited by 299
Steroid Hormone Analysis by Tandem Mass Spectrometry
Soldin, S. J., & Soldin, O. P. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2007.100008 · Cited by 264
Self-citationStandardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Schwarz, E., Liu, A., Randall, H., Haslip, C., Keune, F., Murray, M., Longo, N., & Pasquali, M. (2009) · Pediatric Research · doi:10.1203/pdr.0b013e3181aa3777 · Cited by 97
Use of steroid profiles in determining the cause of adrenal insufficiency
Holst, J. P., Soldin, S. J., Tractenberg, R. E., Guo, T., Kundra, P., Verbalis, J. G., & Jonklaas, J. (2007) · Steroids · doi:10.1016/j.steroids.2006.11.001 · Cited by 67
Self-citation
Metadata
- Authors
- Guo, T., Chan, M., & Soldin, S. J.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2004-04
- Volume
- 128
- Issue
- 4
- Pages
- 469-475
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2138922954
- Cited by
- 93
- References
- 1
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Steroid Profiles Using Liquid Chromatography–Tandem Mass Spectrometry With Atmospheric Pressure Photoionization Source. https://app.cochat.ai/papers/10.5858/2004-128-469-spulcm
- The paper
- Guo, T., Chan, M., & Soldin, S. J. (2004). Steroid Profiles Using Liquid Chromatography–Tandem Mass Spectrometry With Atmospheric Pressure Photoionization Source. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2004-128-469-spulcm
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.