Analytic Bias of Thyroid Function Tests: Analysis of a College of American Pathologists Fresh Frozen Serum Pool by 3900 Clinical Laboratories
Abstract
Context. —In proficiency testing surveys, there are differences in the values reported by users of various analytic methods. Two contributors to this variation are calibrator bias and matrix effects of proficiency testing materials. Objectives. —(1) To quantify the biases of the analytic methods used to measure thyroid-stimulating hormone, thyroxine, triiodothyronine, free thyroxine, and free triiodothyronine levels; (2) to determine if these biases are within allowable limits; and (3) to ascertain if proficiency testing materials correctly identify these biases. Design. —A fresh frozen serum specimen was mailed as part of the 2003 College of American Pathologists Ligand and Chemistry surveys. The means and SDs for each analytic method were determined for this sample as well as for a proficiency testing sample from both surveys. In the fresh frozen serum sample, target values for thyroxine and triiodothyronine were determined by isotope dilution/liquid chromatography/tandem mass spectrometry. All other target values in the study were the median of the means obtained for the various analytic methods. Main Outcome Measures. —Calibration biases were calculated by comparing the mean of each analytic method with the appropriate target values. These biases were evaluated against limits based on intra- and interindividual biological variation. Matrix effects of proficiency testing materials were assessed by comparing the rank of highest to lowest analytic method means (Spearman rank test) for each analyte. Participants. —Approximately 3900 clinical laboratories were enrolled in the College of American Pathologists Chemistry and Ligand surveys. Results. —The number of methods in the Ligand Survey that failed to meet the goals for bias was 7 of 17 for thyroid-stimulating hormone and 11 of 13 for free thyroxine. The failure rates were 12 of 16 methods for thyroxine, 8 of 11 for triiodothyronine, and 9 of 11 for free triiodothyronine. The means of the analytic method for the proficiency testing material correlated significantly ( P < .05) only with the fresh frozen serum means for thyroxine and thyroid-stimulating hormone in the Chemistry Survey and free triiodothyronine in the Ligand Survey. Conclusions. —A majority of the methods used in thyroid function testing have biases that limit their clinical utility. Traditional proficiency testing materials do not adequately reflect these biases.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Differences between the numeric values reported by different fT4 and fT3 methods negatively impact setting universal medical decision points and reference intervals for different patient populations.
“However, differences between the numeric values reported by different fT4 and fT3 methods negatively impact setting universal medical decision points and reference intervals for different patient populations.”
The citation lists haven’t been fetched yet
References 20 · Cited by 66
- Authors
- Steele, B. W., Wang, E., Klee, G. G., Thienpont, L. M., Soldin, S. J., Sokoll, L. J., Winter, W. E., Fuhrman, S. A., & Elin, R. J.
- Affiliations
- Mayo Clinic (US)
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2005-03
- Volume
- 129
- Issue
- 3
- Pages
- 310-317
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2170510427
- Cited by
- 66
- References
- 20
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 4 · 2022: 1 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 9 · 2014: 2 · 2013: 4 · 2012: 4
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Archives of Pathology & Laboratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Keywords
- thyroid function tests, proficiency testing, calibration bias, matrix effects, thyroid-stimulating hormone, thyroxine, triiodothyronine, free thyroxine, free triiodothyronine, isotope dilution mass spectrometry, clinical laboratory methods
- MeSH terms
- Calibration, Data Collection, Humans, Pathology, Clinical, Plasma, Thyroid Function Tests, Thyrotropin, Thyroxine, Triiodothyronine, United States, Observer Variation, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review