Interference From Anti-Streptavidin Antibody
The DOI matches its Crossref record.
Abstract
Immunoassays are commonly used for clinical diagnosis, although interferences have been well documented. The streptavidin-biotin interaction provides an efficient and convenient method to manipulate assay components and is currently used in several immunoassay platforms. To date, there has been no report in the literature of interference from endogenous anti-streptavidin antibodies; however, such antibodies would potentially affect multiple diagnostic platforms. We report results from a patient being treated for thyroid dysfunction who demonstrated a T-uptake result of less than 0.2 and a nonlinear thyroid stimulating hormone dilution that suggested an immunoassay interference. Protein-A sepharose pretreatment corrected the nonlinear dilution and revealed an interference trend of falsely decreased results, as measured by sandwich assay, and falsely elevated results, as measured by competitive assay. The results of streptavidin-agarose adsorption were comparable to adsorption with protein-A sepharose. To our knowledge, this is the first published description of an endogenous anti-streptavidin antibody interfering with clinical laboratory assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm
Favresse, J., Burlacu, M.-C., Maiter, D., & Gruson, D. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00119 · Cited by 258
Variability and Error in Cardiac Troponin Testing
Herman, D. S., Kavsak, P. A., & Greene, D. N. (2017) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqx066 · Cited by 87
Diagnostic procedure in suspected Graves’ disease
Goichot, B., Leenhardt, L., Massart, C., Raverot, V., Tramalloni, J., & Iraqi, H. (2018) · Annales d Endocrinologie · doi:10.1016/j.ando.2018.08.002 · Cited by 32
“• Low TSH: ◦ endogenous anti-TSH antibodies; ◦ heterophile antibodies; ◦ anti-streptavidin antibodies [5,6]; ◦ biotin (dietary supplement or treatment) [7,8].”
BackgroundThe Complex Web of Interferences with Thyroid Function Tests
Al-Bahadili, H., Powers Carson, J., Markov, A., & Jasim, S. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2024.10.007 · Cited by 8
Metadata
- Authors
- Rulander, N. J., Cardamone, D., Senior, M., Snyder, P. J., & Master, S. R.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2013-08-01
- Volume
- 137
- Issue
- 8
- Pages
- 1141-1146
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2010495551
- Cited by
- 63
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.