CoChat

Streamlining Quality Review of Mass Spectrometry Data in the Clinical Laboratory by Use of Machine Learning

Open access
Yu, Min, Bazydlo, Lindsay A. L., Bruns, David E., Harrison, James H. · 2019 · Archives of Pathology & Laboratory Medicine

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Context.—: Turnaround time and productivity of clinical mass spectrometric (MS) testing are hampered by time-consuming manual review of the analytical quality of MS data before release of patient results. Objective.—: To determine whether a classification model created by using standard machine learning algorithms can verify analytically acceptable MS results and thereby reduce manual review requirements. Design.—: We obtained retrospective data from gas chromatography–MS analyses of 11-nor-9-carboxy-delta-9-tetrahydrocannabinol (THC-COOH) in 1267 urine samples. The data for each sample had been labeled previously as either analytically unacceptable or acceptable by manual review. The dataset was randomly split into training and test sets (848 and 419 samples, respectively), maintaining equal proportions of acceptable (90%) and unacceptable (10%) results in each set. We used stratified 10-fold cross-validation in assessing the abilities of 6 supervised machine learning algorithms to distinguish unacceptable from acceptable assay results in the training dataset. The classifier with the highest recall was used to build a final model, and its performance was evaluated against the test dataset. Results.—: In comparison testing of the 6 classifiers, a model based on the Support Vector Machines algorithm yielded the highest recall and acceptable precision. After optimization, this model correctly identified all unacceptable results in the test dataset (100% recall) with a precision of 81%. Conclusions.—: Automated data review identified all analytically unacceptable assays in the test dataset, while reducing the manual review requirement by about 87%. This automation strategy can focus manual review only on assays likely to be problematic, allowing improved throughput and turnaround time without reducing quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/arpa.2018-0238-oa

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 16

Metadata

Authors
Yu, M., Bazydlo, L. A. L., Bruns, D. E., & Harrison, J. H.
Affiliations
University of Kentucky (US)
Corresponding author
Harrison, James H.
ORCID
Yu, Min
Venue
Archives of Pathology & Laboratory Medicine
Published
2019-02-20
Volume
143
Issue
8
Pages
990-998
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W2917394994
Cited by
16
References
25
Citations by year
2025: 4 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 2
FWCI
1.54
Type
journal article
Language
en
Open access
Locations
  • Archives of Pathology & Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
machine learning classification, support vector machine, THC-COOH, urine drug testing, gas chromatography-mass spectrometry
MeSH terms
Machine Learning, Algorithms, Humans, Gas Chromatography-Mass Spectrometry, Reference Standards, Retrospective Studies, Mass Spectrometry, Dronabinol, Reproducibility of Results, Clinical Laboratory Techniques, Automation, Laboratory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Streamlining Quality Review of Mass Spectrometry Data in the Clinical Laboratory by Use of Machine Learning. https://app.cochat.ai/papers/10.5858/arpa.2018-0238-oa
The paper
Yu, M., Bazydlo, L. A. L., Bruns, D. E., & Harrison, J. H. (2019). Streamlining Quality Review of Mass Spectrometry Data in the Clinical Laboratory by Use of Machine Learning. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/arpa.2018-0238-oa

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.