CoChat

REPORT ON A COMPUTER-RANDOMIZED DOUBLE BLIND CLINICAL TRIAL TO DETERMINE THE EFFECTIVENESS OF THE GaAlAs (830 NM) DIODE LASER FOR PAIN ATTENUATION IN SELECTED PAIN GROUPS

Open access
Toya, Shigeo, Motegi, Mitsuo, Inomata, Kenichiro, Ohshiro, Toshio, Maeda, Takashi · 1994 · LASER THERAPY
Cited by 40

The DOI matches its Crossref record.

Abstract

The efficiency of infrared (IR) diode low reactive-level laser therapy (LLLT) has been reported in a variety of pain complaints. In order to ascertain if LLLT is particularly effective in a given pain group, 115 informed and consenting patients in two institutions (Toho University and Keio University, Tokyo, same ambient environmental parameters in treatment rooms) were assigned to groups according to the aetiology of their pain condition. Each patient's name was placed against a number, and a randomization computer program selected either real or sham (placebo) irradiation for each number, and thus each patient. The computer directly controlled the laser system appropriately, and stored the information on disc for retrieval after the trial was finished. The computer was located remotely from the treatment room. Neither the patient nor the therapist knew if they were in the real or placebo group: in placebo therapy, only laser emission was absent, the visible and audible emission indicators behaving exactly as in “real” treatment. The laser used was a gallium aluminium arsenide (GaAlAs) diode laser, 60 mW output, 830 nm, continuous wave. The laser was applied in the contact technique, with an incident power density of ≅ 3 W/cm2, total exposure time per session of from 5-10 min (energy density ≅ 900 ∼ 1800 J/cm2). There were three groups: the extremity joint pain (35), cervical pain (39) and lumbar pain (41) groups. This gave a total of 115 patients (53 female, 62 male, ages from 18∼82, mean age 49.2 ± 15.3). 82% of those who received real treatment in the total population reported effective pain relief, compared with 42% of those who were assigned to receive sham treatment. Following the trial, the data were analyzed statistically applying the χ2 and Fisher’s tests, giving a value of χ2 = 21.328 (df=1), with a value for p = ‹ 0.0001 at a level of confidence of less than 1%, a statistically significant difference for the real versus the placebo treatment. There were no statistically significant differences in the results between the individual pain groups in the two sites. No adverse side effects were reported. It was concluded that diode laser therapy, at the parameters used in the trial, was both safe and effective for alleviation of pain in the groups treated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5978/islsm.94-or-08

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Toya, S., Motegi, M., Inomata, K., Ohshiro, T., & Maeda, T.
Venue
LASER THERAPY
Published
1994
Volume
6
Issue
3
Pages
143-148
ISSN
  • 0898-5901 (ISSN-L)
  • 1884-7269
OpenAlex
W1967269383
Cited by
40
References
0
FWCI
0.74
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: REPORT ON A COMPUTER-RANDOMIZED DOUBLE BLIND CLINICAL TRIAL TO DETERMINE THE EFFECTIVENESS OF THE GaAlAs (830 NM) DIODE LASER FOR PAIN ATTENUATION IN SELECTED PAIN GROUPS. https://app.cochat.ai/papers/10.5978/islsm.94-or-08
The paper
Toya, S., Motegi, M., Inomata, K., Ohshiro, T., & Maeda, T. (1994). REPORT ON A COMPUTER-RANDOMIZED DOUBLE BLIND CLINICAL TRIAL TO DETERMINE THE EFFECTIVENESS OF THE GaAlAs (830 NM) DIODE LASER FOR PAIN ATTENUATION IN SELECTED PAIN GROUPS. LASER THERAPY. https://doi.org/10.5978/islsm.94-or-08

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.