The DOI matches its Crossref record.
Evaluation of Hemostatic Effectiveness in a Standard Swine Hemorrhage Model of Severe Bleeding: A Comparative Study of Chitosan Gauze and Kaolin Gauze
Abstract
Hemorrhage remains a critical factor contributing to avoidable fatalities in combat scenarios and civilian emergencies. Significant advancements have been made in managing extremity hemorrhage through tourniquet application, although not all injuries can be effectively treated with this method. In the United States, the Committee on Tactical Combat Casualty Care (CoTCCC) has emphasized the importance of employing hemostatic dressings during initial trauma care as an alternative when tourniquet application is not feasible. Similar recommendations have been adopted globally, highlighting the pivotal role of topical hemostats in managing such critical situations. Among the recommended topical hemostats, hemostatic gauze, composed of biomaterials including chitosan and kaolin, has demonstrated superior efficacy in rapidly achieving hemostasis. The objective of this study was to evaluate the hemostatic efficacy of axiostat gauze (AG) in an extremity arterial hemorrhage model in swine and compare it with QuikClot Combat Gauze (QCG). The femoral artery was selected to create a model of severe arterial hemorrhage. This model is widely accepted as a standardized combat injury model by military laboratories, including those of the US Department of Defense. The findings indicate that AG has a superior safety profile, evidenced by the absence of particle release, and offers advantages in terms of faster hemostasis, reduced overall blood loss, and greater fluid absorbency compared to QCG. Although AG achieved quicker hemostasis, both AG and QCG ultimately provided effective eventual hemostasis in all animals, demonstrating comparable overall efficacy. In addition to its hemostatic performance, AG also possesses antimicrobial properties and is biocompatible. These attributes make AG a highly effective option for managing severe traumatic bleeding. Thus, AG can be recommended for use in both military and civilian pre-hospital settings as a strategic solution for critical bleeding situations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The results showed that Axiostat has the ability to act as a barrier against bacteria, such as S. aureus, S. epidermidis, Micrococcus luteus, Pseudomonas eruginosa, Escherichia coli and Salmonella abony, and prevent their entry through its surface [21].”
From Evaluation of Chitosan-Based Axiostat as Hemostatic Dressing for Endovascular Procedures in Patients with Leriche Syndrome on Anticoagulant Therapy (2025) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perri, P., Curcio, F., De Luca, M., Piro, P., Trombino, S., & Cassano, R. (2025) · Pharmaceuticals · doi:10.3390/ph18040584 · Cited by 6
Metadata
- Authors
- Kumar, A., Agrawal, A., Bharani, K. K., & Mavely, L.
- Venue
- International Journal of Health Technology and Innovation
- Publisher
- Kalam Institute of Health Technology
- Published
- 2024-08-20
- Volume
- 3
- Issue
- 02
- Pages
- 38-47
- ISSN
- 2583-8547
- Cited by
- 4
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Hemostatic Effectiveness in a Standard Swine Hemorrhage Model of Severe Bleeding: A Comparative Study of Chitosan Gauze and Kaolin Gauze. https://app.cochat.ai/papers/10.60142/ijhti.v3i02.07
- The paper
- Kumar, A., Agrawal, A., Bharani, K. K., & Mavely, L. (2024). Evaluation of Hemostatic Effectiveness in a Standard Swine Hemorrhage Model of Severe Bleeding: A Comparative Study of Chitosan Gauze and Kaolin Gauze. International Journal of Health Technology and Innovation. https://doi.org/10.60142/ijhti.v3i02.07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.