International Journal of Exercise Science 13(7): 1705-1717, 2020. An equation that uses heart rate index (HRI) defined as HR/HRrest to predict oxygen uptake (VO2) in METs (e.g., METs = 6 × HRI ‒ 5) has been developed retrospectively from aggregate data of 60 published studies. However, the prediction error of this model as used by an individual has not been established. Therefore, the purpose of this study was to examine the predictive validity of the HRI equation by comparing submaximal and maximal VO2 predicted by the equation (VO2-Pred) with that measured by indirect calorimetry (VO2-Meas). Sixty healthy adults (age 20.5 ± 2.4 yr., body mass 69.4 ± 13.4 kg, height 1.7 ± 0.1 m) underwent a VO2max test and an experimental trial consisting of a 15-min resting measurement and three successive 10-min treadmill exercise bouts performed at 40%, 60% and 80% of VO2max. VO2 and HR were recorded during both the submaximal and maximal exercises and used to obtain VO2-Pred and VO2-Meas for each intensity and for VO2max. Validation was carried out by paired t-test, regression analysis, and Bland-Altman plots. A modest but significant (p < 0.05) correlation was observed between VO2-Meas and VO2-Pred at 40% (r = 0.58), 60% (r = 0.53), and 80% of VO2max (r = 0.56) and at VO2max (r = 0.50). No differences between VO2-Pred and VO2-Meas were found at 40% (5.53 ± 1.21 vs. 5.28 ± 0.98 METs, respectively) of VO2max, but VO2-Pred was higher (p < 0.05) than VO2-Meas at 60% (8.42 ± 1.77 vs. 7.96 ± 1.39 METs, respectively) and 80% (10.79 ± 2.13 vs. 10.29 ± 1.81 METs, respectively) of VO2max. In contrast, VO2-Pred was lower (p < 0.05) than VO2-Meas at VO2max (12.32 ± 2.30 vs. 13.38 ± 2.24 METs, respectively). Standard errors of the estimate were 0.81, 1.20, 1.54, and 1.97 METs at 40%, 60%, 80% of VO2max and at VO2max, respectively. These results suggest that further investigation aimed to establish the accuracy of using HRI to predict VO2 is warranted.

Overview

CoChat Summary

TL;DR

This study tested the predictive validity of a heart rate index (HRI) equation (METs = 6 × HRI − 5) for estimating oxygen uptake against indirect calorimetry in 60 healthy adults. Correlations were modest and the equation systematically over-predicted submaximal VO2 at 60% and 80% of VO2max while under-predicting at maximal effort.

Key findings

  • Modest but significant (p < 0.05) correlations between measured and predicted VO2 at 40% (r = 0.58), 60% (r = 0.53), 80% of VO2max (r = 0.56), and at VO2max (r = 0.50).
  • No difference between predicted and measured VO2 at 40% of VO2max (5.53 ± 1.21 vs. 5.28 ± 0.98 METs), but predicted VO2 was higher (p < 0.05) at 60% (8.42 ± 1.77 vs. 7.96 ± 1.39 METs) and 80% (10.79 ± 2.13 vs. 10.29 ± 1.81 METs).
  • Predicted VO2 was lower (p < 0.05) than measured at VO2max (12.32 ± 2.30 vs. 13.38 ± 2.24 METs).
  • Standard errors of the estimate were 0.81, 1.20, 1.54, and 1.97 METs at 40%, 60%, 80% of VO2max and at VO2max, respectively.

Methods

  • Sixty healthy adults (age 20.5 ± 2.4 yr, body mass 69.4 ± 13.4 kg, height 1.7 ± 0.1 m) completed a VO2max test and an experimental trial consisting of a 15-min resting measurement and three successive 10-min treadmill exercise bouts at 40%, 60%, and 80% of VO2max.
  • VO2 and HR were recorded during submaximal and maximal exercise to derive predicted (VO2-Pred) and measured (VO2-Meas) values at each intensity and at VO2max.
  • Validation used paired t-tests, regression analysis, and Bland-Altman plots.

Limitations

  • The paper states that further investigation aimed at establishing the accuracy of using HRI to predict VO2 is warranted.
  • Evident from the text: the sample was limited to 60 young, healthy adults (mean age ~20.5 yr), so generalizability to other ages or clinical populations is not established; the available text is the abstract only, so no fuller limitations discussion is provided.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.70252/thpw3818

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 0 Not checked · 9 Own results and interpretations

4 more claims

Create a free account to see all 9 claims and every source verdict.

See all claims — free account

Citations

Cites

Show all 29 references

Cited by

See all 6

Metadata

Authors
Kang, J., Ratamess, N. A., Faigenbaum, A. D., Bush, J. A., Roser, C., Montemarano, D., Mercado, H., Choma, M., Mendez, C., & Pollock, M.
Affiliations
The College of New Jersey (US)
Venue
International Journal of Exercise Science
Published
2020
Volume
13
Issue
7
Pages
1705-1717
ISSN
1939-795X (ISSN-L)
OpenAlex
W3102223811
Cited by
6
References
29
Citations by year
2025: 1 · 2024: 3 · 2023: 1 · 2022: 1
FWCI
0.55
Type
journal article
Language
en
Open access
Licence
cc-by-nd
Locations
  • International journal of exercise science (publishedVersion, cc-by-nd)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • TopSCHOLAR (Western Kentucky University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
oxygen uptake prediction, submaximal exercise, VO2max, prediction error, indirect calorimetry, treadmill exercise, exercise intensity, metabolic equivalents, prediction equation validation, healthy adults, cardiorespiratory fitness assessment, heart rate threshold, heart rate recovery, heart rate variability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Heart Rate Index to Predict Oxygen Uptake – A Validation Study. https://app.cochat.ai/papers/10.70252/thpw3818
The paper
Kang, J., Ratamess, N. A., Faigenbaum, A. D., Bush, J. A., Roser, C., Montemarano, D., Mercado, H., Choma, M., Mendez, C., & Pollock, M. (2020). Use of Heart Rate Index to Predict Oxygen Uptake – A Validation Study. International Journal of Exercise Science. https://doi.org/10.70252/thpw3818

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.