The Cult of the Swan-Ganz Catheter: Overuse and Abuse of Pulmonary Flow Catheters
Abstract
The use of pulmonary artery flow-directed catheters has assumed epidemic proportions without clinical trials establishing improved outcome as a result of their use. During the past 10 years, however, it has become clear that improved outcome is found only in small groups of patients and that use of these catheters is associated with considerable risks of morbidity and mortality. A clinical trial is urgently needed to assess the balance between risks and benefits. While awaiting such trials, physicians should limit catheter use to circumstances in which there is a large probability that the data will result in more effective management; the measurements should only be used to answer specific questions about patient therapy. This situation will occur in a relatively small number of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connors, A. F., McCaffree, D. R., & Gray, B. A. (1983) · New England Journal of Medicine · doi:10.1056/nejm198302033080508 · Cited by 365
Cited by
Gore, J. M., Goldberg, R. J., Spodick, D. H., Alpert, J. S., & Dalen, J. E. (1987) · Chest · doi:10.1378/chest.92.4.721 · Cited by 406
Metadata
- Authors
- ROBIN, E. D.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1985-09-01
- Volume
- 103
- Issue
- 3
- Pages
- 445-449
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2030017517
- Cited by
- 290
- References
- 1
- FWCI
- 23.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Cult of the Swan-Ganz Catheter: Overuse and Abuse of Pulmonary Flow Catheters. https://app.cochat.ai/papers/10.7326/0003-4819-103-3-445
- The paper
- ROBIN, E. D. (1985). The Cult of the Swan-Ganz Catheter: Overuse and Abuse of Pulmonary Flow Catheters. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-103-3-445
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.