Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record.

Adjusted Subcutaneous Heparin or Continuous Intravenous Heparin in Patients with Acute Deep Vein Thrombosis: A Randomized Trial

DOYLE, D. J., TURPIE, A. G. G., HIRSH, J., BEST, C., KINCH, D., LEVINE, M. N., GENT, M. · 1987 · Annals of Internal Medicine

Abstract

STUDY OBJECTIVE: To determine the efficacy and safety of adjusted subcutaneous calcium heparin compared with continuous intravenous calcium heparin as the initial treatment for acute deep vein thrombosis. DESIGN: Randomized control trial. SETTING: University-affiliated general hospital. PATIENTS: Of 111 consecutive patients considered, 103 had acute proximal or calf vein thrombosis confirmed by ascending venography and met all other eligibility criteria. INTERVENTIONS: PATIENTS were randomly assigned to receive subcutaneous or intravenous heparin. The subcutaneous regimen consisted of an initial dose of 15,000 U, adjusted thereafter to prolong the activated partial thromboplastin time to 50 to 70 seconds. The continuous intravenous regimen was begun as a bolus injection of 5000 U, followed by an infusion of 1250 U/h, adjusted to maintain the activated partial thromboplastin time at 50 to 70 seconds. MEASUREMENTS AND MAIN RESULTS: There was no significant difference in the rate of new pulmonary embolism between the two groups, as defined by new high-probability defect on repeat ventilation-perfusion scintigrams of the lung in 96 (93%) of the patients after 7 to 10 days of treatment. Five of forty-seven patients in the subcutaneous group and 5 of 49 in the intravenous group developed pulmonary embolism (95% confidence interval [CI] for the difference, -13.1% to 12.2%). Similarly, there was no significant difference in the frequency of hemorrhagic complications. Five of fifty-one patients in the subcutaneous group and 5 of 52 in the intravenous group had hemorrhagic complications (95% CI for the difference, -11.2% to 11.6%). CONCLUSION: Adjusted subcutaneous calcium heparin may be an effective and safe alternative to continuous intravenous calcium heparin in the initial treatment of acute proximal deep vein thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-107-4-441

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
DOYLE, D. J., TURPIE, A. G. G., HIRSH, J., BEST, C., KINCH, D., LEVINE, M. N., & GENT, M.
Venue
Annals of Internal Medicine
Published
1987-10-01
Volume
107
Issue
4
Pages
441-445
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2068652919
Cited by
171
References
0
FWCI
16.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adjusted Subcutaneous Heparin or Continuous Intravenous Heparin in Patients with Acute Deep Vein Thrombosis: A Randomized Trial. https://app.cochat.ai/papers/10.7326/0003-4819-107-4-441
The paper
DOYLE, D. J., TURPIE, A. G. G., HIRSH, J., BEST, C., KINCH, D., LEVINE, M. N., & GENT, M. (1987). Adjusted Subcutaneous Heparin or Continuous Intravenous Heparin in Patients with Acute Deep Vein Thrombosis: A Randomized Trial. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-107-4-441

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.