The Idle Intravenous Catheter
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the prevalence of idle peripheral intravenous (IV) catheters (those without any therapeutic use) on regular-care medical wards. DESIGN: Observation, interviews, and chart review. SETTING: A university-affiliated VA medical center. PATIENTS: All 959 inpatients on 4 regular-care medical wards during a 6-week period, including 484 IV catheter episodes and 2983 patient-days of IV catheter use. MAIN OUTCOME MEASURE: Idle IV catheter use. RESULTS: Thirty-five percent of all IV catheter episodes (95% CI, 32% to 38%) had 2 or more consecutive idle days. In only 6 of these (1%) could a specific reason for the catheter be determined. Seventeen percent of all patients on regular-care medical wards (CI, 15% to 19%) had an idle IV catheter for 2 or more consecutive days. Twenty percent of all patient-days of IV catheter use were idle (CI, 19% to 21%). CONCLUSIONS: Our data suggest that IV are frequently used unnecessarily. Future efforts to reduce IV catheter complication rates should focus on reducing unnecessary use as well as on improving techniques to reduce infection rates when use is appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“no longer essential [219, 220].”
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Metadata
- Authors
- Lederle, F. A., Parenti, C. M., Berskow, L. C., & Ellingson, K. J.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1992-05-01
- Volume
- 116
- Issue
- 9
- Pages
- 737-738
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1977820523
- Cited by
- 94
- References
- 0
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Idle Intravenous Catheter. https://app.cochat.ai/papers/10.7326/0003-4819-116-9-737
- The paper
- Lederle, F. A., Parenti, C. M., Berskow, L. C., & Ellingson, K. J. (1992). The Idle Intravenous Catheter. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-116-9-737
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.