Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record.

Assessing Housestaff Diagnostic Skills Using a Cardiology Patient Simulator

St. Clair, E. William, Oddone, Eugene Z., Waugh, R. A., Corey, G. Ralph, Feussner, John R. · 1992 · Annals of Internal Medicine

Abstract

OBJECTIVE: To assess the cardiovascular physical examination skills of internal medicine housestaff. DESIGN: Cross-sectional assessment of housestaff performance on three valvular abnormality simulations conducted on the cardiology patient simulator, "Harvey." Evaluations were done at the beginning (session I) and end (session II) of the academic year. SETTING: Duke University Medical Center internal medicine training program. SUBJECTS: Sixty-three (59%) of 107 eligible internal medicine housestaff (postgraduate years 1 through 3) agreed to participate and completed session I; 60 (95%) completed session II. MEASUREMENTS: All volunteers were tested on three preprogrammed simulations (mitral regurgitation, mitral stenosis, and aortic regurgitation). RESULTS: The overall correct response rates for all housestaff were 52% for mitral regurgitation, 37% for mitral stenosis, and 54% for aortic regurgitation. No difference was noted in correct response rates between sessions I and II. For mitral regurgitation, correct assessment of the contour of the holosystolic murmur predicted a correct diagnosis (P = 0.002). For mitral stenosis, identification of an opening snap and proper characterization of the mitral area diastolic murmur predicted a correct diagnosis (P < 0.0001). No individual observations were noted for the aortic regurgitation simulation, whose identification by the housestaff was associated with a correct diagnosis. CONCLUSIONS: Housestaff had difficulty establishing a correct diagnosis for simulations of three common valvular heart diseases. Accurate recognition of a few "key" observations was associated with a correct diagnosis in two of the three diseases. Teaching housestaff to elicit and interpret a few critical signs accurately may improve their physical diagnosis abilities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-117-9-751

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
St. Clair, E. W., Oddone, E. Z., Waugh, R. A., Corey, G. R., & Feussner, J. R.
Venue
Annals of Internal Medicine
Published
1992-11-01
Volume
117
Issue
9
Pages
751-756
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1783460453
Cited by
162
References
0
FWCI
2.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing Housestaff Diagnostic Skills Using a Cardiology Patient Simulator. https://app.cochat.ai/papers/10.7326/0003-4819-117-9-751
The paper
St. Clair, E. W., Oddone, E. Z., Waugh, R. A., Corey, G. R., & Feussner, J. R. (1992). Assessing Housestaff Diagnostic Skills Using a Cardiology Patient Simulator. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-117-9-751

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.