Effect of Fecal Occult Blood Testing on Mortality from Colorectal Cancer: A Case–Control Study
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To estimate by case-control methods the effect of screening using the fecal occult blood test (FOBT) on mortality from colorectal cancer and to examine the relation of that effect to the interval since the most recent screening test. DESIGN: A case-control study. SETTING: The Kaiser Permanente Medical Care Program of Northern California. PATIENTS: A total of 485 persons who developed fatal colorectal cancer after 50 years of age and 727 age- and sex-matched controls. MEASUREMENTS: History of screening FOBTs during the 5 years before case diagnosis. RESULTS: After adjustment for potentially confounding factors, an odds ratio of 0.69 (95% Cl, 0.52 to 0.91) was observed for exposure to at least one screening FOBT during the 5-year interval. The odds ratio was lowest for the first year after the most recent FOBT and rose to 1.00 three years after the last screening examination. False-negative results among cases in the 1 to 2 years before diagnosis contributed substantially to lowering the estimate of efficacy. CONCLUSIONS: These data suggest that a program of annual or biennial screening using FOBTs might lower population risk for mortality from colorectal cancer sufficiently to have important public health implications. However, the confidence intervals around our odds ratio estimates were wide. We therefore believe that additional data will be needed before making recommendations that FOBT screening be expanded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Randomised controlled trial of faecal-occult-blood screening for colorectal cancer
Hardcastle, J. D., Chamberlain, J. O., Robinson, M. H., Moss, S. M., Amar, S. S., Balfour, T. W., James, P. D., & Mangham, C. M. (1996) · The Lancet · doi:10.1016/s0140-6736(96)03386-7 · Cited by 2,793
Randomised study of screening for colorectal cancer with faecal-occult-blood test
Kronborg, O., Fenger, C., Olsen, J., Jørgensen, O. D., & Søndergaard, O. (1996) · The Lancet · doi:10.1016/s0140-6736(96)03430-7 · Cited by 2,501
WINAWER, S. (2003) · Gastroenterology · doi:10.1053/gast.2003.50044 · Cited by 2,143
The Effect of Fecal Occult-Blood Screening on the Incidence of Colorectal Cancer
Mandel, J. S., Church, T. R., Bond, J. H., Ederer, F., Geisser, M. S., Mongin, S. J., Snover, D. C., & Schuman, L. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011303432203 · Cited by 1,423
Design of the prostate, lung, colorectal and ovarian (PLCO) cancer screening trial
Prorok, P. C., Andriole, G. L., Bresalier, R. S., Buys, S. S., Chia, D., David Crawford, E., Fogel, R., Gelmann, E. P., Gilbert, F., Hasson, M. A., et al. (2000) · Controlled Clinical Trials · doi:10.1016/s0197-2456(00)00098-2 · Cited by 1,037
Metadata
- Authors
- Selby, J. V., Friedman, G. D., Quesenberry, Jr., & Weiss, N. S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1993-01-01
- Volume
- 118
- Issue
- 1
- Pages
- 1-6
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2078992272
- Cited by
- 230
- References
- 0
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Fecal Occult Blood Testing on Mortality from Colorectal Cancer: A Case–Control Study. https://app.cochat.ai/papers/10.7326/0003-4819-118-1-199301010-00001
- The paper
- Selby, J. V., Friedman, G. D., Quesenberry, Jr., & Weiss, N. S. (1993). Effect of Fecal Occult Blood Testing on Mortality from Colorectal Cancer: A Case–Control Study. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-118-1-199301010-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.