Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 532

The DOI matches its Crossref record.

Transmission of Infection by Gastrointestinal Endoscopy and Bronchoscopy

Spach, David H., Silverstein, Fred E., Stamm, Walter E. · 1993 · Annals of Internal Medicine

Abstract

OBJECTIVE: To review reports on the transmission of infections by flexible gastrointestinal endoscopy and bronchoscopy in order to determine common infecting microorganisms, circumstances of transmission, and methods of risk reduction. DATA SOURCES: Relevant English-language articles were identified through prominent review articles and a MEDLINE search (1966 to July 1992); additional references were selected from the bibliographies of identified articles. STUDY SELECTION: All selected articles related to transmission of infection by gastrointestinal endoscopy or bronchoscopy; 265 articles were reviewed in detail. DATA SYNTHESIS: Two hundred and eighty-one infections were transmitted by gastrointestinal endoscopy, and 96 were transmitted by gastrointestinal endoscopy, spectrum of these infections ranged from asymptomatic colonization to death. Salmonella species and Pseudomonas aeruginosa were repeatedly identified as the causative agents of infections transmitted by gastrointestinal endoscopy, and Mycobacterium tuberculosis, atypical mycobacteria, and P. aeruginosa were the most common causes of infections transmitted by bronchoscopy. One case of hepatitis B virus transmission via gastrointestinal endoscopy was documented. Major reasons for transmission were improper cleaning and disinfection procedures; the contamination of endoscopes by automatic washers; and an inability to decontaminate endoscopes, despite the use of standard disinfection techniques, because of their complex channel and valve systems. CONCLUSIONS: The most common agents of infection transmitted by endoscopy are Salmonella, Pseudomonas, and Mycobacterium species. To prevent endoscopic transmission of infections, recommended disinfection guidelines must be followed, the effectiveness of automatic washers must be carefully monitored, and improvements in endoscope design are needed to facilitate effective cleaning and disinfection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-118-2-199301150-00008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 532

Metadata

Authors
Spach, D. H., Silverstein, F. E., & Stamm, W. E.
Venue
Annals of Internal Medicine
Published
1993-01-15
Volume
118
Issue
2
Pages
117-128
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1999453172
Cited by
532
References
0
FWCI
15.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transmission of Infection by Gastrointestinal Endoscopy and Bronchoscopy. https://app.cochat.ai/papers/10.7326/0003-4819-118-2-199301150-00008
The paper
Spach, D. H., Silverstein, F. E., & Stamm, W. E. (1993). Transmission of Infection by Gastrointestinal Endoscopy and Bronchoscopy. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-118-2-199301150-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.