CoChat

The Safety and Diagnostic Accuracy of Minibronchoalveolar Lavage in Patients with Suspected Ventilator-Associated Pneumonia

Kollef, Marin H., Bock, Kevin R., Richards, Rodger D., Hearns, Mona L. · 1995 · Annals of Internal Medicine
Cited by 210

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To assess the safety of minibronchoalveolar lavage done by respiratory therapists for the evaluation of suspected ventilator-associated pneumonia and to determine the diagnostic agreement between quantitative lower airway cultures obtained by the minibronchoalveolar lavage and protected specimen brush techniques. DESIGN: A prospective direct comparison of two diagnostic techniques. SETTING: An academic tertiary care center in St. Louis, Missouri. PATIENTS: 72 consecutive patients suspected of having ventilator-associated pneumonia on the basis of clinical evidence. INTERVENTIONS: Sampling of lower airway secretions using the protected specimen brush and minibronchoalveolar lavage techniques. MAIN OUTCOME MEASURES: Clinical complications and quantitative cultures of respiratory secretions. RESULTS: 72 patients suspected of having ventilator-associated pneumonia (first episode) were evaluated using minibronchoalveolar lavage. In 42 patients, lower airway secretions were also obtained using the protected specimen brush technique. No change in arterial blood oxygen saturation or heart rate occurred after minibronchoalveolar lavage (P > 0.2). Mean arterial pressure slightly increased with minibronchoalveolar lavage (baseline mean pressure, 90.1 mm Hg [CI, 88.4 to 91.7 mm Hg]; average within-person change, 2.6 mm Hg; P = 0.024). Good diagnostic agreement was shown for quantitative cultures obtained with the protected specimen brush and minibronchoalveolar lavage techniques (kappa statistic, 0.63; concordance, 83.3%); 10(3) colony forming units/mL was used as the threshold for a clinically significant culture result. CONCLUSIONS: Minibronchoalveolar lavage is a safe and technically simple procedure for obtaining quantitative lower airway cultures in patients requiring mechanical ventilation. Quantitative culture results obtained by minibronchoalveolar lavage are similar to those obtained by the protected specimen brush technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-122-10-199505150-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Kollef, M. H., Bock, K. R., Richards, R. D., & Hearns, M. L.
Venue
Annals of Internal Medicine
Published
1995-05-15
Volume
122
Issue
10
Pages
743-748
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1989058723
Cited by
210
References
0
FWCI
8.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Safety and Diagnostic Accuracy of Minibronchoalveolar Lavage in Patients with Suspected Ventilator-Associated Pneumonia. https://app.cochat.ai/papers/10.7326/0003-4819-122-10-199505150-00002
The paper
Kollef, M. H., Bock, K. R., Richards, R. D., & Hearns, M. L. (1995). The Safety and Diagnostic Accuracy of Minibronchoalveolar Lavage in Patients with Suspected Ventilator-Associated Pneumonia. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-122-10-199505150-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.