The Urinary Metanephrine-to-Creatinine Ratio for the Diagnosis of Pheochromocytoma
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To compare the operating characteristics of two tests for diagnosing pheochromocytoma: 1) measurement of the ratio between urinary metanephrine and creatinine levels and 2) measurement of urinary metanephrine levels alone. A second objective was to ascertain the reasons for false-positive test results. DESIGN: Cross-sectional study. SETTING: Hypertension referral center. PATIENTS: 1013 patients referred for hypertension and tested for pheochromocytoma. MEASUREMENTS: 24-hour urinary levels of metanephrine (measured using liquid chromatography) and creatinine. The presence of pheochromocytoma was confirmed at surgery. In patients with positive test results, the absence of pheochromocytoma was documented by negative results of retests and imaging procedures. RESULTS: Of 58 patients with increased metanephrine levels or increased metanephrine-to-creatinine ratios, 20 had pheochromocytoma and 38 did not. Of the 38 patients without pheochromocytoma, 15 had high metanephrine levels but normal metanephrine-to-creatinine ratios. The respective operating characteristics of measurement of urinary metanephrine levels and measurement of the metanephrine-to-creatinine ratio were as follows: sensitivity, 95% and 100%; specificity, 98% and 98%; positive predictive value, 46% and 47%; and negative predictive value, 100% and 100%. In 13 of the 23 patients who had a high metanephrine-to-creatinine ratio, various acute events may have caused hypersecretion of catecholamines. CONCLUSIONS: Measurement of the metanephrine-to-creatinine ratio is a sensitive and specific test for pheochromocytoma. However, acute events may increase urinary metanephrine excretion to the level that occurs with tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best?
Lenders, J. W. M., Pacak, K., Walther, M. M., Linehan, W. M., Mannelli, M., Friberg, P., Keiser, H. R., Goldstein, D. S., & Eisenhofer, G. (2002) · JAMA · doi:10.1001/jama.287.11.1427 · Cited by 1,134
Amar, L., Baudin, E., Burnichon, N., Peyrard, S., Silvera, S., Bertherat, J., Bertagna, X., Schlumberger, M., Jeunemaitre, X., Gimenez-Roqueplo, A.-P., et al. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-0709 · Cited by 450
Self-citationAmar, L., Servais, A., Gimenez-Roqueplo, A.-P., Zinzindohoue, F., Chatellier, G., & Plouin, P.-F. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1398 · Cited by 390
Self-citationEisenhofer, G., Lenders, J. W. M., Linehan, W. M., Walther, M. M., Goldstein, D. S., & Keiser, H. R. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402404 · Cited by 349
Cawood, T. J., Hunt, P. J., O'Shea, D., Cole, D., & Soule, S. (2009) · European Journal of Endocrinology · doi:10.1530/eje-09-0234 · Cited by 300
Metadata
- Authors
- Heron, E., Chatellier, G., Billaud, E., Foos, E., & Plouin, P.-F.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1996-08-15
- Volume
- 125
- Issue
- 4
- Pages
- 300-303
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2006152010
- Cited by
- 88
- References
- 0
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Urinary Metanephrine-to-Creatinine Ratio for the Diagnosis of Pheochromocytoma. https://app.cochat.ai/papers/10.7326/0003-4819-125-4-199608150-00008
- The paper
- Heron, E., Chatellier, G., Billaud, E., Foos, E., & Plouin, P.-F. (1996). The Urinary Metanephrine-to-Creatinine Ratio for the Diagnosis of Pheochromocytoma. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-125-4-199608150-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.