The Electrocardiographic Exercise Test in a Population with Reduced Workup Bias: Diagnostic Performance, Computerized Interpretation, and Multivariable Prediction
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Empirical scores, computerized ST-segment measurements, and equations have been proposed as tools for improving the diagnostic performance of the exercise test. OBJECTIVE: To compare the diagnostic utility of these scores, measurements, and equations with that of visual ST-segment measurements in patients with reduced workup bias. DESIGN: Prospective analysis. SETTING: 12 university-affiliated Veterans Affairs Medical Centers. PATIENTS: 814 consecutive patients who presented with angina pectoris and agreed to undergo both exercise testing and coronary angiography. MEASUREMENTS: Digital electrocardiographic recorders and angiographic calipers were used for testing at each site, and test results were sent to core laboratories. RESULTS: Although 25% of patients had previously had testing, workup bias was reduced, as shown by comparison with a pilot study group. This reduction resulted in a sensitivity of 45% and a specificity of 85% for visual analysis. Computerized measurements and visual analysis had similar diagnostic power. Equations incorporating nonelectrocardiographic variables and either visual or computerized ST-segment measurement had similar discrimination and were superior to single ST-segment measurements. These equations correctly classified 5 more patients of every 100 tested (areas under the receiver-operating characteristic curve, 0.80 for equations and 0.68 for visual analysis; P < 0.001) in this population with a 50% prevalence of disease. CONCLUSIONS: Standard exercise tests had lower sensitivity but higher specificity in this population with reduced work-up bias than in previous studies. Computerized ST-segment measurements were similar to visual ST-segment measurements made by cardiologists. Considering more than ST-segment measurements can enhance the diagnostic power of the exercise test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gibbons, R. J., Balady, G. J., Beasley, J. W., FAAFP, Bricker, J. T., Duvernoy, W. F. C., Froelicher, V. F., Mark, D. B., Marwick, T. H., McCallister, B. D., et al. (1997) · Circulation · doi:10.1161/01.cir.96.1.345 · Cited by 1,094
Self-citationExercise-induced ST depression in the diagnosis of coronary artery disease. A meta-analysis.
Gianrossi, R., Detrano, R., Mulvihill, D., Lehmann, K., Dubach, P., Colombo, A., McArthur, D., & Froelicher, V (1989) · Circulation · doi:10.1161/01.cir.80.1.87 · Cited by 846
Self-citationExercise standards. A statement for health professionals from the American Heart Association.
Fletcher, G. F., Froelicher, V. F., Hartley, L. H., Haskell, W. L., & Pollock, M. L. (1990) · Circulation · doi:10.1161/01.cir.82.6.2286 · Cited by 723
Self-citationUse of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Exercise Treadmill Score for Predicting Prognosis in Coronary Artery Disease
MARK, D. B., HLATKY, M. A., HARRELL, F. E., LEE, K. L., CALIFF, R. M., & PRYOR, D. B. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-106-6-793 · Cited by 671 · cited 1×
“Angina during testing was classified according to the Duke Angina Index (2 if angina required that the test be stopped, 1 if angina occurred during or after the test, and 0 if no angina occurred) (8).”
MethodThe Diagnostic Performance of Computer Programs for the Interpretation of Electrocardiograms
Willems, J. L., Abreu-Lima, C., Arnaud, P., van Bemmel, J. H., Brohet, C., Degani, R., Denis, B., Gehring, J., Graham, I., van Herpen, G., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199112193252503 · Cited by 539
Nomogram based on metabolic equivalents and age for assessing aerobic exercise capacity in men.
Morris, C. K., Myers, J., Froelicher, V. F., Kawaguchi, T., Ueshima, K., & Hideg, A. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90832-l · Cited by 280 · cited 2×
“The inclusion of normal persons exaggerates the performance of heart rate correction algorithms because of the differences in maximum heart rate between normal persons and patients with chest pain (29, 30).”
BackgroundSelf-citationA nomogram to predict exercise capacity from a specific activity questionnaire and clinical data
Myers, J., Do, D., Herbert, W., Ribisl, P., & Froelicher, V. F. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90340-9 · Cited by 234 · cited 1×
“All patients had exercise testing done with a ramp treadmill protocol (7).”
MethodSelf-citationMorise, A. P., & Diamond, G. A. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90072-1 · Cited by 191 · cited 2×
“In one of the few studies in which workup bias was lessened, the sensitivity was 40% and the specificity was 96% (16); these results are similar to ours.”
ResultMethodologic problems of exercise testing for coronary artery disease: Groups, analysis and bias
Philbrick, J. T., Horwitz, R. I., & Feinstein, A. R. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90432-4 · Cited by 179
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Committee Members, Gibbons, R. J., Balady, G. J., Timothy Bricker, J., Chaitman, B. R., Fletcher, G. F., Froelicher, V. F., Mark, D. B., McCallister, B. D., Mooss, A. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000034670.06526.15 · Cited by 2,607
Self-citationFletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
ACC/AHA 2002 guideline update for exercise testing: summary article
Gibbons, R. J., Balady, G. J., Timothy Bricker, J., Chaitman, B. R., Fletcher, G. F., Froelicher, V. F., Mark, D. B., McCallister, B. D., Mooss, A. N., O’Reilly, M. G., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02164-2 · Cited by 1,229
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00831-7 · Cited by 791
Self-citationGibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Circulation · doi:10.1161/01.cir.102.1.126 · Cited by 508
Self-citation2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0224 · Cited by 418
Qaseem, A., Fihn, S. D., Williams, S., Dallas, P., Owens, D. K., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-10-201211200-00010 · Cited by 393
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
2014 ESC/EACTS Guidelines on myocardial revascularization
Windecker, S., Kolh, P., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy14m09_01 · Cited by 328
Punglia, R. S., D'Amico, A. V., Catalona, W. J., Roehl, K. A., & Kuntz, K. M. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021659 · Cited by 326
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Risk of sports: do we need a pre-participation screening for competitive and leisure athletes?
Corrado, D., Schmied, C., Basso, C., Borjesson, M., Schiavon, M., Pelliccia, A., Vanhees, L., & Thiene, G. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq482 · Cited by 231
Lauer (2005) · doi:10.1161/circulationaha.105.166543 · Cited by 220
Exercise Electrocardiogram Testing: Beyond the ST Segment
Kligfield, P., & Lauer, M. S. (2006) · Circulation · doi:10.1161/circulationaha.105.561944 · Cited by 195
Aktas, M. K. (2004) · JAMA · doi:10.1001/jama.292.12.1462 · Cited by 193
Automated Diagnosis of Coronary Artery Disease Based on Data Mining and Fuzzy Modeling
Tsipouras, M. G., Exarchos, T. P., Fotiadis, D. I., Kotsia, A. P., Vakalis, K. V., Naka, K. K., & Michalis, L. K. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.907985 · Cited by 189
Exercise testing in clinical medicine
Ashley, E. A., Myers, J., & Froelicher, V. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03138-x · Cited by 186
Self-citationThe prognostic value of exercise testing in elderly men.
Spin, J. M., Prakash, M., Froelicher, V. F., Partington, S., Marcus, R., Do, D., & Myers, J. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01065-3 · Cited by 64
Self-citationCurtis, J. M., Horton, E. S., Bahnson, J., Gregg, E. W., Jakicic, J. M., Regensteiner, J. G., Ribisl, P. M., Soberman, J. E., Stewart, K. J., Espeland, M. A., et al. (2010) · Diabetes Care · doi:10.2337/dc09-1787 · Cited by 37
“This definition provides a sensitivity of 45% and a specificity of 85% for coronary artery disease diagnosed by angiography (21).”
Background
Metadata
- Authors
- Froelicher, V. F., Lehmann, K. G., Thomas, R., Goldman, S., Morrison, D., Edson, R., Lavori, P., Myers, J., Dennis, C., Shabetai, R., Do, D., Froning, J., & and The Veterans Affairs Cooperative Study in Health Services #016 (QUEXTA) Study Group*
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1998-06-15
- Volume
- 128
- Issue
- 12_Part_1
- Pages
- 965-974
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2159465923
- Cited by
- 218
- References
- 22
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.