Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record.

Transesophageal Echocardiography To Assess Embolic Risk in Patients with Atrial Fibrillation

Stollberger, Claudia, Chnupa, Pavel, Kronik, Gerhard, Brainin, Michael, Finsterer, Josef, Schneider, Barbara, Slany, Jorg · 1998 · Annals of Internal Medicine

Abstract

BACKGROUND: Transesophageal echocardiography visualizes the left atrium and its appendage, thrombi, and spontaneous echocardiographic contrast. OBJECTIVE: To assess the association of transesophageal echocardiographic characteristics with stroke or embolism in atrial fibrillation. DESIGN: Multicenter observational follow-up study. SETTING: Hospitals in Austria and Slovakia. PATIENTS: 409 outpatients with nonrheumatic atrial fibrillation and without recent stroke. INTERVENTION: Patients with thrombi received anticoagulation, and patients without thrombi received aspirin. MEASUREMENTS: Primary events were stroke or embolism. Secondary events were death not caused by stroke or embolism and need for anticoagulation. RESULTS: In the left atrium or left atrial appendage, 10 patients (2.5%) had thrombi and 47 (12%) had spontaneous echocardiographic contrast. The appendage had a mean (+/- SD) length of 44+/-10 mm, a mean width of 23+/-6 mm, and a mean area of 5.8+/-2.5 cm2. Follow-up ranged from 1 to 74 months (mean, 58 months). Fifty patients had stroke or embolism, 53 died of a cause other than stroke or embolism, and 38 required anticoagulation. On univariate analysis, thrombi (risk ratio, 3.9 [95% CI, 1.4 to 10.1]; P = 0.009), length of the left atrial appendage (risk ratio, 1.6 [CI, 1.05 to 2.5]; P = 0.03), and width of the left atrial appendage (risk ratio, 2.4 [CI, 1.2 to 4.81; P = 0.01) were associated with stroke or embolism. Multivariate analysis identified hypertension (risk ratio, 3.6 [CI, 1.8 to 8.4]; P = 0.001), previous stroke (risk ratio, 3.7 [CI, 1.5 to 7.5]; P = 0.002), and age (risk ratio, 1.1 [CI, 1.0 to 1.11; P < 0.001) as risk factors for stroke or embolism and provided evidence of an association between thrombi and stroke or embolism (risk ratio, 2.4 [CI, 0.9 to 6.9]; P = 0.09). CONCLUSIONS: In outpatients with atrial fibrillation and without recent stroke, thrombi of the left atrium or left atrial appendage and length and width of the left atrial appendage were associated with stroke or embolism in univariate analysis. In a multivariate analysis, age, hypertension, and previous stroke were risk factors for stroke or embolism, and thrombi of the left atrium or left atrial appendage were possible risk factors. In these patients, history may be more useful than transesophageal echocardiography for the assessment of embolic risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-128-8-199804150-00004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Stollberger, C., Chnupa, P., Kronik, G., Brainin, M., Finsterer, J., Schneider, B., & Slany, J.
Venue
Annals of Internal Medicine
Published
1998-04-15
Volume
128
Issue
8
Pages
630-638
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1978894460
Cited by
169
References
0
FWCI
10.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transesophageal Echocardiography To Assess Embolic Risk in Patients with Atrial Fibrillation. https://app.cochat.ai/papers/10.7326/0003-4819-128-8-199804150-00004
The paper
Stollberger, C., Chnupa, P., Kronik, G., Brainin, M., Finsterer, J., Schneider, B., & Slany, J. (1998). Transesophageal Echocardiography To Assess Embolic Risk in Patients with Atrial Fibrillation. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-128-8-199804150-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.