Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Clinical, Hemodynamic, and Cardiopulmonary Exercise Test Determinants of Survival in Patients Referred for Evaluation of Heart Failure

Myers, Jonathan, Gullestad, Lars, Vagelos, Randall, Do, Dat, Bellin, Daniel, Ross, Heather, Fowler, Michael B.·1998·Annals of Internal Medicine

Abstract

BACKGROUND: Accurate prognosis in chronic heart failure has become increasingly important in assessing the efficacy of treatment and in appropriately allocating scarce resources for transplantation. Previous studies of severe heart failure have been limited by short follow-up periods and few deaths. OBJECTIVE: To establish clinical, hemodynamic, and cardiopulmonary exercise test determinants of survival in patients with heart failure. DESIGN: Retrospective study. SETTING: Hospital-based outpatient heart failure clinic. PARTICIPANTS: 644 patients referred for evaluation of heart failure over 10 years. MEASUREMENTS: Age, cause of heart failure, body surface area, cardiac index, ejection fraction, pulmonary capillary wedge pressure, left ventricular dimensions, watts achieved during exercise, heart rate, maximum systolic blood pressure, and oxygen uptake (VO2) at the ventilatory threshold and at peak exercise were measured at baseline. Univariate and multivariate analyses were done for clinical, hemodynamic, and exercise test predictors of death. A Cox hazards model was developed for time of death. RESULTS: During a mean follow-up period of 4 years, 187 patients (29%) died and 101 underwent transplantation. Actuarial 1-year and 5-year survival rates were 90.5% and 73.4%, respectively. Resting systolic blood pressure, watts achieved, peak VO2, VO2 at the ventilatory threshold, and peak heart rate were greater among survivors than among nonsurvivors. Cause of heart failure (coronary artery disease or cardiomyopathy) was a strong determinant of death (relative risk for coronary artery disease, 1.73; P< 0.01). By multivariate analysis, only peak VO2 was a significant predictor of death. Stratification of peak VO2 above and below 12, 14, and 16 mL/kg per minute demonstrated significant differences in risk for death, but each cut-point predicted risk to a similar degree. CONCLUSIONS: Peak VO2 outperforms clinical variables, right-heart catheterization data, exercise time, and other exercise test variables in predicting outcome in severe chronic heart failure. Direct measurement of VO2 should be included when clinical or surgical decisions are being made in patients referred for evaluation of heart failure or those considered for transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-129-4-199808150-00004

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 271

Metadata

Authors
Myers, J., Gullestad, L., Vagelos, R., Do, D., Bellin, D., Ross, H., & Fowler, M. B.
Venue
Annals of Internal Medicine
Published
1998-08-15
Volume
129
Issue
4
Pages
286-293
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2075778690
Cited by
271
References
24
FWCI
19.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical, Hemodynamic, and Cardiopulmonary Exercise Test Determinants of Survival in Patients Referred for Evaluation of Heart Failure. https://app.cochat.ai/papers/10.7326/0003-4819-129-4-199808150-00004
The paper
Myers, J., Gullestad, L., Vagelos, R., Do, D., Bellin, D., Ross, H., & Fowler, M. B. (1998). Clinical, Hemodynamic, and Cardiopulmonary Exercise Test Determinants of Survival in Patients Referred for Evaluation of Heart Failure. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-129-4-199808150-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.