Prospective Study of Color Duplex Ultrasonography Compared with Contrast Venography in Patients Suspected of Having Deep Venous Thrombosis of the Upper Extremities
Abstract
BACKGROUND: The optimal strategy for diagnosis of deep venous thrombosis (DVT) is less well established for the upper extremities than for the lower extremities. Duplex color ultrasonography can be difficult to perform in the upper extremities because of their anatomy, and contrast venography is often indicated. Moreover, limited data exist on the use of duplex color ultrasonography in this setting. OBJECTIVE: To determine the accuracy of duplex ultrasonography for diagnosis of DVT of the upper extremities. DESIGN: Prospective study of duplex ultrasonography compared with venography. SETTING: A teaching hospital in Amsterdam, the Netherlands. PATIENTS: 126 consecutive inpatients and outpatients with suspected DVT of the upper extremities. MEASUREMENTS: Contrast venography was obtained after duplex ultrasonography and was judged independently. A three-step protocol, involving compression ultrasonography, color ultrasonography, and color Doppler ultrasonography, was used. Sensitivity, specificity, and likelihood ratios for ultrasonography as a whole were calculated. The independent value of each step was assessed. RESULTS: Venography and ultrasonography were not feasible in 23 of 126 patients (18%) and 1 of 126 patients (0.8%), respectively. Results of ultrasonography were inconclusive in 3 patients. Venography demonstrated thrombosis in 44 of 99 patients (44%); in 36 patients (36%), thrombosis was related to intravenous catheters or malignant disease. Sensitivity and specificity of duplex ultrasonography were 82% (95% CI, 70% to 93%) and 82% (CI, 72% to 92%), respectively. Venous incompressibility correlated well with thrombosis, whereas only 50% of isolated flow abnormalities proved to be thrombosis-related. CONCLUSIONS: Duplex ultrasonography may be the method of choice for initial diagnosis of patients with suspected thrombosis of the upper extremities. However, in patients with isolated flow abnormalities, contrast venography should be performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Likelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932 · cited 1×
“We calculated diagnostic accuracy (sensitivity and specificity), likelihood ratios (25), and 95% CIs for all findings except indeterminate findings on duplex color ultrasonography (because comparison with contrast venography was not possible).”
MethodEvaluating diagnostic tests with imperfect standards
Valenstein, P. N. (1990) · American Journal of Clinical Pathology · doi:10.1093/ajcp/93.2.252 · Cited by 220 · cited 1×
“If tests are considered independently, sensitivity and specificity are usually underestimated slightly (28).”
Background
Cited by
Bates, S. M., Jaeschke, R., Stevens, S. M., Goodacre, S., Wells, P. S., Stevenson, M. D., Kearon, C., Schunemann, H. J., Crowther, M., Pauker, S. G., et al. (2012) · Chest · doi:10.1378/chest.11-2299 · Cited by 686
The RUSH Exam: Rapid Ultrasound in SHock in the Evaluation of the Critically lll
Perera, P., Mailhot, T., Riley, D., & Mandavia, D. (2010) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2009.09.010 · Cited by 671
Venous Thromboembolism Associated With Long-Term Use of Central Venous Catheters in Cancer Patients
Verso, M., & Agnelli, G. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.08.008 · Cited by 605
Management of occlusion and thrombosis associated with long-term indwelling central venous catheters
Baskin, J. L., Pui, C.-H., Reiss, U., Wilimas, J. A., Metzger, M. L., Ribeiro, R. C., & Howard, S. C. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60220-8 · Cited by 445
Lim, W., Le Gal, G., Bates, S. M., Righini, M., Haramati, L. B., Lang, E., Kline, J. A., Chasteen, S., Snyder, M., Patel, P., et al. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018024828 · Cited by 418
Metadata
- Authors
- Baarslag, H.-J., van Beek, E. J. R., Koopman, M. M. W., & Reekers, J. A.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2002-06-18
- Volume
- 136
- Issue
- 12
- Pages
- 865-872
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2000501927
- Cited by
- 196
- References
- 2
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective Study of Color Duplex Ultrasonography Compared with Contrast Venography in Patients Suspected of Having Deep Venous Thrombosis of the Upper Extremities. https://app.cochat.ai/papers/10.7326/0003-4819-136-12-200206180-00007
- The paper
- Baarslag, H.-J., van Beek, E. J. R., Koopman, M. M. W., & Reekers, J. A. (2002). Prospective Study of Color Duplex Ultrasonography Compared with Contrast Venography in Patients Suspected of Having Deep Venous Thrombosis of the Upper Extremities. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-136-12-200206180-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.