CoChat

Diagnosis of Lower-Limb Deep Venous Thrombosis: A Prospective Blinded Study of Magnetic Resonance Direct Thrombus Imaging

Fraser, Douglas G.W., Moody, Alan R., Morgan, Paul S., Martel, Anne L., Davidson, Ian · 2002 · Annals of Internal Medicine
Cited by 280

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Current magnetic resonance techniques generate high signal from venous blood and show thrombi as filling defects. Magnetic resonance direct thrombus imaging (MRDTI) directly visualizes acute thrombus. OBJECTIVE: To determine the accuracy of MRDTI for diagnosis of acute symptomatic deep venous thrombosis (DVT) below and above the knee. DESIGN: Prospective, blinded study. SETTING: A 1355-bed university hospital. PATIENTS: 101 patients with suspected DVT who had had routine venography. Participants were recruited from a cohort of patients with suspected DVT. All patients with a positive venogram and one quarter of patients with a negative venogram were selected by using a random sequence. INTERVENTION: MRDTI was performed within 48 hours of venography and was interpreted by two reviewers. MEASUREMENTS: Diagnosis of DVT overall; isolated calf, femoropopliteal, and ileofemoral DVT; and thrombus in the calf, femoropopliteal, and iliac segments. RESULTS: The reports from two readers had sensitivities of 96% and 94% and specificities of 90% and 92% for diagnosis of DVT. Sensitivities were 92% and 83% for isolated calf DVT, 97% and 97% for femoropopliteal DVT, and 100% and 100% for ileofemoral DVT. Specificities were 94% and 96% for isolated calf DVT and 100% and 100% for both femoropopliteal and ileofemoral DVT. Similarly, sensitivity and specificity within each of the venous segments ranged from 91% to 100%. Interobserver variability measured by using a weighted kappa statistic ranged from 0.89 to 0.98 for these measures. CONCLUSION: Magnetic resonance direct thrombus imaging is an accurate noninvasive test for diagnosis of DVT, and its accuracy is maintained below the knee. Comparison of individual venous segments showed that results of MRDTI agreed strongly with findings on venography. Scanning was well tolerated, and interpretation was highly reproducible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-136-2-200201150-00006

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 280

Metadata

Authors
Fraser, D. G. W., Moody, A. R., Morgan, P. S., Martel, A. L., & Davidson, I.
Venue
Annals of Internal Medicine
Published
2002-01-15
Volume
136
Issue
2
Pages
89-98
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W1964493710
Cited by
280
References
16
FWCI
14.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of Lower-Limb Deep Venous Thrombosis: A Prospective Blinded Study of Magnetic Resonance Direct Thrombus Imaging. https://app.cochat.ai/papers/10.7326/0003-4819-136-2-200201150-00006
The paper
Fraser, D. G. W., Moody, A. R., Morgan, P. S., Martel, A. L., & Davidson, I. (2002). Diagnosis of Lower-Limb Deep Venous Thrombosis: A Prospective Blinded Study of Magnetic Resonance Direct Thrombus Imaging. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-136-2-200201150-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.