BACKGROUND: The Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II demonstrated that implantable cardioverter defibrillators (ICDs) save lives when used in patients with a history of myocardial infarction (MI) and an ejection fraction of 0.3 or less. OBJECTIVE: To investigate the cost-effectiveness of implanting ICDs in patients who met MADIT-II eligibility criteria and were enrolled in the Duke Cardiovascular Database between 1 January 1986 and 31 December 2001. DESIGN: Cost-effectiveness analysis. DATA SOURCES: Published literature, databases owned by Duke University Medical Center, and Medicare data. TARGET POPULATION: Adults with a history of MI and an ejection fraction of 0.3 or less. TIME HORIZON: Lifetime. PERSPECTIVE: Societal. INTERVENTIONS: ICD therapy versus conventional medical therapy. OUTCOMES MEASURES: Cost per life-year gained and incremental cost-effectiveness. RESULTS: Compared with conventional medical therapy, ICDs are projected to result in an increase of 1.80 discounted years in life expectancy and an incremental cost-effectiveness ratio of 50,500 dollars per life-year gained. Cost-effectiveness varied dramatically with changes in time horizon: The cost-effectiveness ratio increased to 67,800 dollars per life-year gained, 79,900 dollars per life-year gained, 100,000 dollars per life-year gained, 167,900 dollars per life-year gained, and 367,200 dollars per life-year gained for 15-year, 12-year, 9-year, 6-year, and 3-year time horizons, respectively. Changing the frequency of follow-up visits, complication rates, and battery replacements had less of an effect on the cost-effectiveness ratios than reducing the cost of ICD placement and leads. LIMITATIONS: The study was limited by the completeness of the data, referral bias, difference in medical therapy between the Duke cohort and the MADIT-II cohort, and not addressing potential upgrades to biventricular devices. CONCLUSIONS: The economic expense of defibrillator implantation in all patients who meet MADIT-II eligibility criteria is substantial. However, in the range of survival benefit observed in MADIT-II, ICD therapy for these patients is economically attractive by conventional standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-142-8-200504190-00007

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 119

Metadata

Authors
Al-Khatib, S. M., Anstrom, K. J., Eisenstein, E. L., Peterson, E. D., Jollis, J. G., Mark, D. B., Li, Y., O'Connor, C. M., Shaw, L. K., & Califf, R. M.
Venue
Annals of Internal Medicine
Published
2005-04-19
Volume
142
Issue
8
Pages
593-600
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2097325636
Cited by
119
References
5
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical and Economic Implications of the Multicenter Automatic Defibrillator Implantation Trial-II. https://app.cochat.ai/papers/10.7326/0003-4819-142-8-200504190-00007
The paper
Al-Khatib, S. M., Anstrom, K. J., Eisenstein, E. L., Peterson, E. D., Jollis, J. G., Mark, D. B., Li, Y., O'Connor, C. M., Shaw, L. K., & Califf, R. M. (2005). Clinical and Economic Implications of the Multicenter Automatic Defibrillator Implantation Trial-II. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-142-8-200504190-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.