Effect of a Second-Generation Venous Catheter Impregnated with Chlorhexidine and Silver Sulfadiazine on Central Catheter–Related Infections: A Randomized, Controlled Trial
Abstract
BACKGROUND: Central venous catheter-related infections are a significant medical problem. Improved preventive measures are needed. OBJECTIVE: To ascertain 1) effectiveness of a second-generation antiseptic-coated catheter in the prevention of microbial colonization and infection; 2) safety and tolerability of this device; 3) microbiology of infected catheters; and 4) propensity for the development of antiseptic resistance. DESIGN: Multicenter, randomized, double-blind, controlled trial. SETTING: 9 university-affiliated medical centers. PATIENTS: 780 patients in intensive care units who required central venous catheterization. INTERVENTION: Patients received either a standard catheter or a catheter coated with chlorhexidine and silver sulfadiazine. MEASUREMENTS: The authors assessed catheter colonization and catheter-related infection, characterized microbes by molecular typing, and determined their susceptibility to antiseptics. Patient tolerance of the catheter was monitored. RESULTS: Patients with the 2 types of catheters had similar demographic features, clinical interventions, laboratory values, and risk factors for infection. Antiseptic catheters were less likely to be colonized at the time of removal compared with control catheters (13.3 vs. 24.1 colonized catheters per 1000 catheter-days; P < 0.01). The center-stratified Cox regression hazard ratio for colonization controlling for sampling design and potentially confounding variables was 0.45 (95% CI, 0.25 to 0.78). The rate of definitive catheter-related bloodstream infection was 1.24 per 1000 catheter-days (CI, 0.26 to 3.62 per 1000 catheter-days) for the control group versus 0.42 per 1000 catheter-days (CI, 0.01 to 2.34 per 1000 catheter-days) for the antiseptic catheter group (P = 0.6). Coagulase-negative staphylococci and other gram-positive organisms were the most frequent microbes to colonize catheters. Noninfectious adverse events were similar in both groups. Antiseptic susceptibility was similar for microbes recovered from either group. LIMITATIONS: The antiseptic catheter was not compared with an antibiotic-coated catheter, and no conclusion can be made regarding its effect on bloodstream infection. CONCLUSIONS: The second-generation chlorhexidine-silver sulfadiazine catheter is well tolerated. Antiseptic coating appears to reduce microbial colonization of the catheter compared with an uncoated catheter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationChurch, D., Elsayed, S., Reid, O., Winston, B., & Lindsay, R. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.2.403-434.2006 · Cited by 1,876
Lebeaux, D., Ghigo, J.-M., & Beloin, C. (2014) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00013-14 · Cited by 1,318
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Self-citationKostakioti, M., Hadjifrangiskou, M., & Hultgren, S. J. (2013) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a010306 · Cited by 999
Metadata
- Authors
- Rupp, M. E., Lisco, S. J., Lipsett, P. A., Perl, T. M., Keating, K., Civetta, J. M., Mermel, L. A., Lee, D., Dellinger, E. P., Donahoe, M., Giles, D., Pfaller, M. A., Maki, D. G., & Sherertz, R.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2005-10-18
- Volume
- 143
- Issue
- 8
- Pages
- 570-580
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2154156472
- Cited by
- 233
- References
- 0
- FWCI
- 23.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of a Second-Generation Venous Catheter Impregnated with Chlorhexidine and Silver Sulfadiazine on Central Catheter–Related Infections: A Randomized, Controlled Trial. https://app.cochat.ai/papers/10.7326/0003-4819-143-8-200510180-00007
- The paper
- Rupp, M. E., Lisco, S. J., Lipsett, P. A., Perl, T. M., Keating, K., Civetta, J. M., Mermel, L. A., Lee, D., Dellinger, E. P., Donahoe, M., Giles, D., Pfaller, M. A., Maki, D. G., & Sherertz, R. (2005). Effect of a Second-Generation Venous Catheter Impregnated with Chlorhexidine and Silver Sulfadiazine on Central Catheter–Related Infections: A Randomized, Controlled Trial. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-143-8-200510180-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.