Relationship between Clinical Performance Measures and Outcomes among Patients Receiving Long-Term Hemodialysis
The DOI matches its Crossref record.
Abstract
BACKGROUND: Patients receiving long-term hemodialysis have a yearly mortality rate of 15% to 20%. OBJECTIVE: To determine whether attaining clinical performance measures for hemodialysis care is associated with favorable 12-month mortality and hospitalization rates. DESIGN: Cohort study. SETTING: Outpatient hemodialysis centers in the United States. PATIENTS: 15 287 patients who were selected from a 5% random sample of patients receiving long-term hemodialysis. MEASUREMENTS: The authors used data from the Centers for Medicare & Medicaid Services End-Stage Renal Disease Clinical Performance Measures Project from 1999 and 2000. The clinical performance measure targets were hemoglobin value of 110 g/L or greater; serum albumin value of 40 g/L or greater or 37 g/L or greater (bromcresol green and bromcresol purple laboratory methods, respectively); use of a fistula for vascular access; and measured single-pool Kt/V urea value of 1.2 or greater. The outcome measures were death or hospitalization during 1-year follow-up. RESULTS: 8364 patients (54.7%) were hospitalized and 3062 (20.0%) died during the 12-month follow-up period. Six percent of patients did not meet any clinical measure targets, 24% met 1 target, 39% met 2 targets, 24% met 3 targets, and 7% met all 4 targets. The unadjusted 12-month hospitalization and mortality rates for these 5 groups were 60%, 60%, 56%, 49%, and 43% (P < 0.001) and 29%, 25%, 21%, 14%, and 7% (P < 0.001), respectively. The risk for death increased for each additional guideline indicator that was not met: Adjusted hazard ratios were 4.6 (95% CI, 3.3 to 6.4), 3.5 (CI, 2.6 to 4.7), 2.6 (CI, 1.9 to 3.5), and 1.9 (CI, 1.4 to 2.6) for 0, 1, 2, or 3 targets met, respectively, compared with meeting 4 targets (referent). Similarly, the risk for hospitalization increased for each additional guideline indicator that was not met: Adjusted hazard ratios were 1.6 (CI, 1.4 to 1.9), 1.5 (CI, 1.3 to 1.7), 1.3 (CI, 1.1 to 1.5), and 1.1 (CI, 0.98 to 1.3), respectively. LIMITATIONS: It was not possible to determine the roles of severity of illness, other patient factors, or suboptimal care in failure to meet performance measures. CONCLUSIONS: In patients receiving long-term hemodialysis, meeting multiple clinical measure targets is associated with a decrease in hospitalization and mortality rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Levey, A. S., & Coresh, J. (2012) · The Lancet · doi:10.1016/s0140-6736(11)60178-5 · Cited by 1,841
Low Health Literacy Associates with Increased Mortality in ESRD
Cavanaugh, K. L., Wingard, R. L., Hakim, R. M., Eden, S., Shintani, A., Wallston, K. A., Huizinga, M. M., Elasy, T. A., Rothman, R. L., & Ikizler, T. A. (2010) · Journal of the American Society of Nephrology · doi:10.1681/asn.2009111163 · Cited by 274
Serum Albumin as a Predictor of Mortality in Peritoneal Dialysis: Comparisons With Hemodialysis
Mehrotra, R., Duong, U., Jiwakanon, S., Kovesdy, C. P., Moran, J., Kopple, J. D., & Kalantar-Zadeh, K. (2011) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2011.03.018 · Cited by 250
“Serum albumin was a key measure that was included in the Core Indicators Project, which has now been replaced by the Clinical Performance Measures Project.(2,3) Although serum albumin level is not an approved clinical performance measure, it still is reported in the annual report “as an indicator for assessing mortali…”
Levey, A. S., Schoolwerth, A. C., Burrows, N. R., Williams, D. E., Stith, K. R., & McClellan, W. (2009) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2008.11.019 · Cited by 227
Self-citationGuía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Rocco, M. V., Frankenfield, D. L., Hopson, S. D., & McClellan, W. M.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2006-10-03
- Volume
- 145
- Issue
- 7
- Pages
- 512-519
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2054042253
- Cited by
- 111
- References
- 0
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship between Clinical Performance Measures and Outcomes among Patients Receiving Long-Term Hemodialysis. https://app.cochat.ai/papers/10.7326/0003-4819-145-7-200610030-00009
- The paper
- Rocco, M. V., Frankenfield, D. L., Hopson, S. D., & McClellan, W. M. (2006). Relationship between Clinical Performance Measures and Outcomes among Patients Receiving Long-Term Hemodialysis. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-145-7-200610030-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.