CoChat

Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography: A Randomized Validation Study

Mulgrew, Alan T., Fox, Nurit, Ayas, Najib T., Ryan, C. Frank · 2007 · Annals of Internal Medicine

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Polysomnography (PSG), despite limited availability and high cost, is currently recommended for diagnosis of obstructive sleep apnea and titration of effective continuous positive airway pressure (CPAP). OBJECTIVE: To test the utility of a diagnostic algorithm in conjunction with ambulatory CPAP titration in initial management of obstructive sleep apnea. DESIGN: A randomized, controlled, open-label trial that compared standard PSG with ambulatory CPAP titration in high-risk patients identified by a diagnostic algorithm. SETTING: A tertiary referral sleep disorders program in Vancouver, British Columbia, Canada. PATIENTS: 68 patients with a high pretest probability of moderate to severe obstructive sleep apnea (apnea-hypopnea index [AHI] >15 episodes/h) identified by sequential application of the Epworth Sleepiness Scale (ESS) score, Sleep Apnea Clinical Score, and overnight oximetry. INTERVENTION: Patients were randomly assigned to PSG or ambulatory titration by using a combination of auto-CPAP and overnight oximetry. They were observed for 3 months. MEASUREMENTS: Apnea-hypopnea index on CPAP, ESS score, quality of life, and CPAP adherence. RESULTS: The PSG and ambulatory groups had similar median BMI (38 kg/m2), age (55 years), ESS score (14 points), and respiratory disturbance index (31 episodes of respiratory disturbance/h). Each episode is determined by a computer algorithm based on analysis of oxygen saturation measured by pulse oximetry. After 3 months, there were no differences in the primary outcome, AHI on CPAP (median, 3.2 vs. 2.5; difference, 0.8/h [95% CI, -0.9 to 2.3]) (P = 0.31), between the PSG and ambulatory groups, or in the secondary outcomes, ESS score, Sleep Apnea Quality of Life Index, and CPAP. Adherence to CPAP therapy was better in the ambulatory group than in the PSG group (median, 5.4 vs. 6.0; difference, -1.12 h/night [CI, -2.0 to 0.2]) (P = 0.021). CONCLUSIONS: In the initial management of patients with a high probability of obstructive sleep apnea, PSG confers no advantage over the ambulatory approach in terms of diagnosis and CPAP titration. The ambulatory approach may improve adherence to treatment. When access to PSG is inadequate, the ambulatory approach can be used to expedite management of patients most in need of treatment.

Overview

Integrity signals

Registry

Crossref · 10.7326/0003-4819-146-3-200702060-00004

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 40 references

Research works printed but not linked: 3

  1. 1994, American Thoracic Society. Official statement adopted March 1944. Am J Respir Crit Care Med, 150, 1738
  2. 1997, Polysomnography Task Force, American Sleep Disorders Association Standards of Practice Committee. Sleep, 20, 406
  3. 1999, The Report of an American Academy of Sleep Medicine Task Force. Sleep, 22, 667

Cited by

See all 403

Metadata

Authors
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F.
Affiliations
  • University of British Columbia (CA)
  • From University of British Columbia and Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada.
Venue
Annals of Internal Medicine
Published
2007-02-06
Volume
146
Issue
3
Pages
157-166
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2130340796
Cited by
368
References
40
Citations by year
2026: 1 · 2025: 7 · 2024: 3 · 2023: 12 · 2022: 14 · 2021: 7 · 2020: 11 · 2019: 6 · 2018: 9 · 2017: 18 · 2016: 12 · 2015: 29 · 2014: 20 · 2013: 35 · 2012: 30
FWCI
25.60
Type
journal article
Language
en
Open access
closed
Licence
www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
Locations
  • Annals of Internal Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, polysomnography, auto-CPAP, CPAP adherence, diagnostic algorithm, nocturnal oximetry, apnea-hypopnea index, Epworth Sleepiness Scale, quality of life, medication adherence, high-risk patients, polysomnography alternative, sleep disorder diagnosis, continuous positive airway pressure
MeSH terms
Adult, Algorithms, Ambulatory Care, Cross-Sectional Studies, Double-Blind Method, Female, Humans, Male, Middle Aged, Oximetry, Patient Compliance, Prospective Studies, Quality of Life, Sensitivity and Specificity, Patient Satisfaction, Polysomnography, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography: A Randomized Validation Study. https://app.cochat.ai/papers/10.7326/0003-4819-146-3-200702060-00004
The paper
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007). Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography: A Randomized Validation Study. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-146-3-200702060-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.