The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cryo-EM single particle analysis with the Volta phase plate
Open accessAbstract
We present a method for in-focus data acquisition with a phase plate that enables near-atomic resolution single particle reconstructions. Accurate focusing is the determining factor for obtaining high quality data. A double-area focusing strategy was implemented in order to achieve the required precision. With this approach we obtained a 3.2 Å resolution reconstruction of the Thermoplasma acidophilum 20S proteasome. The phase plate matches or slightly exceeds the performance of the conventional defocus approach. Spherical aberration becomes a limiting factor for achieving resolutions below 3 Å with in-focus phase plate images. The phase plate could enable single particle analysis of challenging samples in terms of small size, heterogeneity and flexibility that are difficult to solve by the conventional defocus approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Cited by
Zivanov, J., Nakane, T., & Scheres, S. H. W. (2020) · IUCrJ · doi:10.1107/s2052252520000081 · Cited by 781
Cryo-EM structures of STING reveal its mechanism of activation by cyclic GMP–AMP
Shang, G., Zhang, C., Chen, Z. J., Bai, X.-C., & Zhang, X. (2019) · Nature · doi:10.1038/s41586-019-0998-5 · Cited by 757
Breaking Cryo-EM Resolution Barriers to Facilitate Drug Discovery
Merk, A., Bartesaghi, A., Banerjee, S., Falconieri, V., Rao, P., Davis, M. I., Pragani, R., Boxer, M. B., Earl, L. A., Milne, J. L. S., et al. (2016) · Cell · doi:10.1016/j.cell.2016.05.040 · Cited by 504
Unravelling biological macromolecules with cryo-electron microscopy
Fernandez-Leiro, R., & Scheres, S. H. W. (2016) · Nature · doi:10.1038/nature19948 · Cited by 413
Cryo-electron microscopy for structural analysis of dynamic biological macromolecules
Murata, K., & Wolf, M. (2018) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.07.020 · Cited by 331
Metadata
- Authors
- Danev, R., & Baumeister, W.
- Venue
- eLife
- Publisher
- eLife Sciences Publications, Ltd
- Published
- 2016-03-07
- Volume
- 5
- ISSN
- 2050-084X (ISSN-L)
- OpenAlex
- W2301646104
- Cited by
- 159
- References
- 2
- FWCI
- 15.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryo-EM single particle analysis with the Volta phase plate. https://app.cochat.ai/papers/10.7554/elife.13046
- The paper
- Danev, R., & Baumeister, W. (2016). Cryo-EM single particle analysis with the Volta phase plate. eLife. https://doi.org/10.7554/elife.13046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.