Cited by 3Musculoskeletal pain and rehabilitationSpine and Intervertebral Disc PathologyReliability and Agreement in Measurement

Inter-Rater and Test-Retest Reliabilities of Lumbar Stiffness Measurement in the Postero-Anterior Direction Using a Portable Algometer and the Kinovea Program

Open access
Yodchaisarn, Wantanee, Rungruangbaiyok, Sunthorn, de Lourdes Pereira, Maria, Rungruangbaiyok, Chadapa·2023·PeerJ

Abstract

Background: Back pain negatively impacts a person's quality of life and can cause major disability or even death. The measurement of spinal stiffness can be utilized as a promising tool to guide therapeutic decisions regarding physical therapy that result in effective back pain management. This study aimed to determine the reliability of instrumented postero-anterior (PA) stiffness assessment of the lumbar spine in asymptomatic participants by novice assessors using a portable algometer and the Kinovea program. Methods: Thirty asymptomatic participants aged 18-25 years were enrolled in this study. Two novice assessors examined the participants for lumbar spinal stiffness at L1-L5 for two consecutive days. The algometer was applied to measure the PA force that applied to each lumbar. The stiffness assessment of each lumbar region was recorded as a video. The 600 data sets of assessment videos were imported into the Kinovea program to perform displacement measurements of each lumbar level. Spinal displacement values at 15 N were defined by graph plotting between force and displacement. The spinal stiffness values were defined by slope calculation. Both variables were analyzed for inter-rater and test-retest reliabilities using intra-class correlation coefficients (ICCs) and standard error of measurement (SEM). Bland-Altman analysis was applied to assess the inter-rater and test-retest systematical bias and limits of agreement of measuring displacement and stiffness. Results: The inter-rater reliability of measuring the displacement and the stiffness of L1-L5 was moderate to good (displacement ICCs: 0.67-0.83, stiffness ICCs: 0.60-0.83). The test-retest reliability of measuring the displacement and stiffness of L1-L5 were moderate to good, ICCs: 0.57-0.86 and ICCs: 0.51-0.88, respectively. The inter-rater analysis's Bland-Altman plot showed that the systematic bias was 0.83 when measuring displacement and 0.20 when measuring stiffness and the bias of both parameters were in both directions. While the test-retest systematically biased measurements of displacement and stiffness were -0.26 mm and 0.22 N/mm, respectively, and the bias of both parameters were in both directions. Conclusions: The moderate-to-good inter-rater and test-retest reliabilities of the portable instrumented spinal stiffness assessment using a digital algometer and the Kinovea program by novice assessors were demonstrated in this study. Bland-Altman analysis showed that measuring stiffness was more stable and had less systematic bias than measuring displacement. To figure out how reliable the device is in general, more comprehensive studies should be comparatively conducted in the future on subgroups of patients with normal vertebra, hypomobile or hypermobile conditions.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7717/peerj.16148

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Previous literature evaluating sagittal plane kinematics with Kinovea uniformly reports robust reliability coefficients (ICC > 0.80) for hip, knee, and ankle angles, pelvic alignment, lumbar lordosis, and trunk tilt.

    “previous literature evaluating sagittal plane kinematics with Kinovea, which uniformly reports robust reliability coefficients (ICC > 0.80) for hip, knee, and ankle angles [32], pelvic alignment [31], lumbar lordosis [46,47], and trunk tilt [48].”

    From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [47]

    The Abstract’s Methods describe Kinovea measurements of postero-anterior lumbar displacement and stiffness, not sagittal-plane angles or lumbar lordosis. The Abstract’s Results report ICC ranges beginning at 0.51–0.67, contrary to the claim that this source uniformly reports ICCs above 0.80. (LLM, conf=0.86)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 29 · Cited by 3

Authors
Yodchaisarn, W., Rungruangbaiyok, S., de Lourdes Pereira, M., & Rungruangbaiyok, C.
Affiliations
  • Walailak University (TH)
  • Rajamangala University of Technology Srivijaya (TH)
  • CICECO - Aveiro Institute of Materials & Department of Medical Sciences, University of Aveiro, Aveiro, Portugal
Corresponding author
Rungruangbaiyok, Chadapa
Venue
PeerJ
Publisher
PeerJ
Published
2023-10-02
Volume
11
Pages
e16148
ISSN
2167-8359 (ISSN-L)
OpenAlex
W4387260405
Cited by
3
References
29
Citations by year
2026: 2 · 2025: 1
FWCI
0.47
Type
journal article
Language
en
Open access
Locations
  • PeerJ (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Greater South Information System
Funders
Walailak University
Topics
  • Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Spine and Intervertebral Disc Pathology
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
Kinovea video analysis, inter-rater reliability, test-retest reliability, back pain, physiotherapy assessment, measurement bias, asymptomatic participants, force-displacement curves, standard error of measurement
MeSH terms
Adolescent, Adult, Back Pain, Humans, Lumbar Vertebrae, Lumbosacral Region, Quality of Life, Reproducibility of Results, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review