The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Consumer grade EEG devices: are they usable for control tasks?
Open accessAbstract
We present the evaluation of two well-known, low-cost consumer-grade EEG devices: the Emotiv EPOC and the Neurosky MindWave. Problems with using the consumer-grade EEG devices (BCI illiteracy, poor technical characteristics, and adverse EEG artefacts) are discussed. The experimental evaluation of the devices, performed with 10 subjects asked to perform concentration/relaxation and blinking recognition tasks, is given. The results of statistical analysis show that both devices exhibit high variability and non-normality of attention and meditation data, which makes each of them difficult to use as an input to control tasks. BCI illiteracy may be a significant problem, as well as setting up of the proper environment of the experiment. The results of blinking recognition show that using the Neurosky device means recognition accuracy is less than 50%, while the Emotiv device has achieved a recognition accuracy of more than 75%; for tasks that require concentration and relaxation of subjects, the Emotiv EPOC device has performed better (as measured by the recognition accuracy) by ∼9%. Therefore, the Emotiv EPOC device may be more suitable for control tasks using the attention/meditation level or eye blinking than the Neurosky MindWave device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aftanas, L. I., & Golocheikine, S. A. (2001) · Neuroscience Letters · doi:10.1016/s0304-3940(01)02094-8 · Cited by 865
Towards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501
Psycho-physiological measures for assessing cognitive load
Haapalainen, E., Kim, S., Forlizzi, J. F., & Dey, A. K. (2010) · Proceedings of the 12th ACM international conference on Ubiquitous computing · doi:10.1145/1864349.1864395 · Cited by 382
Cited by
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
EEG Analytics for Early Detection of Autism Spectrum Disorder: A data-driven approach
Bosl, W. J., Tager-Flusberg, H., & Nelson, C. A. (2018) · Scientific Reports · doi:10.1038/s41598-018-24318-x · Cited by 381
Emotion Recognition for Human-Robot Interaction: Recent Advances and Future Perspectives
Spezialetti, M., Placidi, G., & Rossi, S. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.532279 · Cited by 293
Consumer Grade EEG Measuring Sensors as Research Tools: A Review
Sawangjai, P., Hompoonsup, S., Leelaarporn, P., Kongwudhikunakorn, S., & Wilaiprasitporn, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2962874 · Cited by 267
Metadata
- Authors
- Maskeliunas, R., Damasevicius, R., Martisius, I., & Vasiljevas, M.
- Venue
- PeerJ
- Publisher
- PeerJ
- Published
- 2016-03-22
- Volume
- 4
- Pages
- e1746
- ISSN
- 2167-8359 (ISSN-L)
- OpenAlex
- W2304788182
- Cited by
- 210
- References
- 3
- FWCI
- 15.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.