Cited by 0Clinical Laboratory Practices and Quality ControlEmergency and Acute Care StudiesElectronic Health Records Systems

Implementation of a Point-of-Care Blood Testing System in a Canadian Emergency Department: A Mixed-Methods Evaluation of Workflow and Clinician Perceptions

Open access
Allam, Sarah, McGowan, Melissa, Nolan, Brodie·2026·Cureus

Abstract

OBJECTIVE: Point-of-care blood gas and chemistry testing is commonly used in emergency care to provide rapid biochemical information during initial patient assessment. We evaluated the implementation of the Siemens Healthineers ePOC Blood Analysis System in a tertiary-care Canadian emergency department (ED) by assessing clinician-perceived usability, adequacy of training, satisfaction, and perceived effects on workflow and clinical decision-making. METHODS: This quality-improvement and implementation evaluation was reported in accordance with the Standards for Quality Improvement Reporting Excellence (SQUIRE) 2.0 guidelines, where applicable. The evaluation consisted of (1) a retrospective analysis of core laboratory turnaround times (TATs) during the early implementation period and (2) a post-implementation survey assessing clinician-reported usability, adequacy of training, satisfaction, and perceived effects on workflow efficiency and clinical decision-making. Results: From March to April 2025, the device was used in 42 adult ED patients; 28/42 (66.7%) cases had core laboratory TAT data available. The mean core laboratory TAT was 18 minutes (range: 0-33) for blood gas syringe samples and nine minutes (range: 0-19) for plasma samples. From August to October 2025, 32 clinicians completed the survey. Most respondents reported using ePOC at least monthly (31/32, 96.9%), and 21/32 (65.6%) rated it as easy or very easy to use. Among 29 respondents to the training item, 16 (55.2%) felt training was adequate, while eight (27.6%) felt it was inadequate. Reported benefits included improved efficiency of blood analysis (24/30, 80.0%), shorter time to critical results (25/31, 80.6%), and faster clinical decision-making (25/30, 83.3%). Overall, 24/32 (75.0%) respondents were satisfied or very satisfied, and 29/32 (90.6%) supported continued ED use. Reported barriers included calibration delays, lack of direct electronic medical record integration, and perceived concerns regarding agreement with laboratory values. CONCLUSION: Clinician responses were generally supportive of ePOC use, but perceptions of inadequate training and workflow challenges suggest that its benefits may depend on a more structured implementation approach.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7759/cureus.114077

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 17

Authors
Allam, S., McGowan, M., & Nolan, B.
Affiliations
  • University of Toronto (CA)
  • St. Michael's Hospital (CA)
Corresponding author
Allam, Sarah
Venue
Cureus
Published
2026-08-06
Volume
18
Issue
8
Pages
e114077-e114077
ISSN
2168-8184 (ISSN-L)
OpenAlex
W7196927311
Cited by
0
References
17
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Cureus (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Emergency Medicine › Emergency and Acute Care Studies
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
Keywords
point-of-care testing, blood gas analysis, emergency department, implementation evaluation, clinician perceptions, usability, clinician training, laboratory turnaround time, workflow efficiency, clinical decision-making, electronic health record integration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review