Translabial ultrasonography and placenta previa: does measurement of the os-placenta distance predict outcome?
The DOI matches its Crossref record.
Abstract
The aim of this study was to assess the value of the measurement of os-placenta distance by translabial ultrasonography in the evaluation of placenta previa. This method was used in 40 women with suspected placenta previa to measure the distance between the placenta and internal cervical os. Sonographic diagnoses were compared to placental location determined at delivery. Translabial ultrasonography proved superior to the transabdominal route in both diagnosis and exclusion of placenta previa. Measurement of the os-placenta distance can be used as an adjunct to clinical assessment to predict the likelihood of safe vaginal delivery in cases of suspected placenta previa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Persistence of Placenta Previa According to Gestational Age at Ultrasound Detection
Dashe, J. S., McIntire, D. D., Ramus, R. M., Santos-Ramos, R., & Twickler, D. M. (2002) · Obstetrics & Gynecology · doi:10.1097/00006250-200205000-00005 · Cited by 242
Bhide, A., Prefumo, F., Moore, J., Hollis, B., & Thilaganathan, B. (2003) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2003.02491.x · Cited by 154
“Dawson et al.4 used translabial ultrasound in 40 women with suspected placenta praevia with an average interval of six weeks between ultrasound and delivery.”
BackgroundMethodInfluentialUsing ultrasound in the clinical management of placental implantation abnormalities
Vintzileos, A. M., Ananth, C. V., & Smulian, J. C. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2015.05.059 · Cited by 145
Diagnosis of low‐lying placenta: can migration in the third trimester predict outcome?
Oppenheimer, L., Holmes, P., Simpson, N., & Dabrowski, A. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00450.x · Cited by 102
“We have confirmed a previous finding 14,15 that a placenta in the lower uterine segment should not be clinically labeled as placenta previa if the edge is greater than 20 mm away from the internal cervical os at any gestational age.”
ResultPlacenta previa: distance to internal os and mode of delivery
Vergani, P., Ornaghi, S., Pozzi, I., Beretta, P., Russo, F. M., Follesa, I., & Ghidini, A. (2009) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.06.009 · Cited by 85
Al Wadi, K., Schneider, C., Burym, C., Reid, G., Hunt, J., & Menticoglou, S. (2014) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(15)30508-9 · Cited by 25
Metadata
- Authors
- Dawson, W. B., Dumas, M. D., Romano, W. M., Gagnon, R., Gratton, R. J., & Mowbray, R. D.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 1996-06
- Volume
- 15
- Issue
- 6
- Pages
- 441-446
- ISSN
- 0278-4297 (ISSN-L)
- OpenAlex
- W1825295377
- Cited by
- 63
- References
- 0
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.