Three‐dimensional sonographic assessment of fetal behavior in the early second trimester of pregnancy.
The DOI matches its Crossref record.
Abstract
To evaluate the fetal behavior pattern in the early second trimester of pregnancy by use of specially developed abdominal dynamic three‐dimensional sonography. Dynamic three‐dimensional sonographic examinations were performed on 11 healthy pregnant women at 14 to 18 weeks of gestation. This imaging system provided continuous three‐dimensional sonographic images every 1 to 2 seconds. Fetal movements were recorded continuously for 60 minutes in each fetus. The rate of occurrence of head, mouth, arm, trunk, and leg movements was evaluated. All fetal behavioral patterns were observed during the period studied. The active phase (time with fetal movements) was 59.4%, and the resting phase was 40.6%. The most active fetal behavior pattern was an arm movement, whereas the least was a mouth movement. Moreover, each fetal movement was synchronized and harmonized with other fetal movements (a few movement patterns were found to be generated simultaneously). Dynamic three‐dimensional sonography provides a novel means for evaluation of fetal behavior in the early second trimester of pregnancy. These results suggest that dynamic three‐dimensional sonography may be an important modality in future early fetal behavior research and in evaluation of early fetal well‐being.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The potential of 4D sonography in the assessment of fetal behavior in high-risk pregnancies
Talic, A., Kurjak, A., Ahmed, B., Stanojevic, M., Predojevic, M., Kadic, A. S., & Di Renzo, G. C. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2010.534830 · Cited by 327
Normal fetal motility: an overview
de Vries, J. I. P., & Fong, B. F. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2740 · Cited by 213
Kurjak, A., Azumendi, G., Andonotopo, W., & Salihagic-Kadic, A. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2006.06.090 · Cited by 168
Recognition of facial expression of fetuses by artificial intelligence (AI)
Miyagi, Y., Hata, T., Bouno, S., Koyanagi, A., & Miyake, T. (2021) · Journal of Perinatal Medicine · doi:10.1515/jpm-2020-0537 · Cited by 34
Self-citationFetal face as important indicator of fetal brain function
AboEllail, M. A. M., & Hata, T. (2017) · Journal of Perinatal Medicine · doi:10.1515/jpm-2016-0377 · Cited by 33
Self-citation
Metadata
- Authors
- Kuno, A., Akiyama, M., Yamashiro, C., Tanaka, H., Yanagihara, T., & Hata, T.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2001-12
- Volume
- 20
- Issue
- 12
- Pages
- 1271-1275
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2140855935
- Cited by
- 84
- References
- 0
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three‐dimensional sonographic assessment of fetal behavior in the early second trimester of pregnancy. https://app.cochat.ai/papers/10.7863/jum.2001.20.12.1271
- The paper
- Kuno, A., Akiyama, M., Yamashiro, C., Tanaka, H., Yanagihara, T., & Hata, T. (2001). Three‐dimensional sonographic assessment of fetal behavior in the early second trimester of pregnancy. Journal of Ultrasound in Medicine. https://doi.org/10.7863/jum.2001.20.12.1271
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.