Perceived Difficulty and Success Rate of Standard Versus Ultrasound‐Guided Peripheral Intravenous Cannulation in a Novice Study Group: A Randomized Crossover Trial
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objectives: To our knowledge, no previous studies have evaluated the perceived levels of difficulty between traditional and ultrasound (US)‐guided peripheral intravenous (IV) access in the novice provider. We attempt to show that, in a group of medical students who have limited peripheral IV experience, US‐guided peripheral IV cannulation can be achieved more effectively and with a lesser degree of difficulty than standard peripheral IV cannulation. Methods: We performed a randomized crossover study of 61 first‐ and second‐year medical students. After a 1‐hour training session, participants were randomized to either standard cannulation on a standard peripheral IV trainer or US‐guided cannulation on a standard US IV trainer. Results: One hundred percent (61 of 61) of the participants in the US‐guided IV group successfully achieved cannulation versus 56% (34 of 61) of the participants in the standard IV group (P < .001). The average number of attempts to obtain access in the US‐guided IV group was 1.31 versus 2.16 in the standard IV group (P < .001). The average difficulty score assigned to US‐guided cannulation was 2.81 of 10 versus 3.90 of 10 in the standard IV group (P = .003). Conclusions: Our study shows a decrease in perceived difficulty and a concomitant increased ability to cannulate a vein using US versus traditional landmark guidance techniques, even in the novice phlebotomist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Ultrasound-guidance vs. standard technique in difficult vascular access patients by ed technicians
Bauman, M., Braude, D., & Crandall, C. (2009) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.02.005 · Cited by 160
Predictors of Success in Nurse-Performed Ultrasound-Guided Cannulation
Chinnock, B., Thornton, S., & Hendey, G. W. (2007) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.02.027 · Cited by 81
Cited by
Lamperti, M., Biasucci, D. G., Disma, N., Pittiruti, M., Breschan, C., Vailati, D., Subert, M., Traškaitė, V., Macas, A., Estebe, J.-P., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001180 · Cited by 316
van Loon, F. H. J., Buise, M. P., Claassen, J. J. F., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.047 · Cited by 195
Tran, Q. K., Fairchild, M., Yardi, I., Mirda, D., Markin, K., & Pourmand, A. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.07.002 · Cited by 49
Anderssen, L. M., Petersen, M. S., Wang, A. G., Mohr, M., & Fjallheim, A. S. (2026) · The Journal of Vascular Access · doi:10.1177/11297298251347816 · Cited by 11
Metadata
- Authors
- Vitto, M. J., Myers, M., Vitto, C. M., & Evans, D. P.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2016-03-23
- Volume
- 35
- Issue
- 5
- Pages
- 895-898
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2310138744
- Cited by
- 47
- References
- 3
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.