Interobserver Variability of Sonography for Prediction of Placenta Accreta
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objectives: The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Methods: Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal‐fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator‐specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. Results: A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Conclusions: Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maternal Morbidity Associated With Multiple Repeat Cesarean Deliveries
Silver, R. M., Landon, M. B., Rouse, D. J., Leveno, K. J., Spong, C. Y., Thom, E. A., Moawad, A. H., Caritis, S. N., Harper, M., Wapner, R. J., et al. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000219750.79480.84 · Cited by 1,909
Self-citationOptimal management strategies for placenta accreta
Eller, A., Porter, T., Soisson, P., & Silver, R. (2009) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.02037.x · Cited by 578
Self-citationEller, A. G., Bennett, M. A., Sharshiner, M., Masheter, C., Soisson, A. P., Dodson, M., & Silver, R. M. (2011) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182051db2 · Cited by 556
Self-citationBelfort, M. A. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.09.013 · Cited by 484
Committee Opinion No. 529: Placenta Accreta
(2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e318262e340 · Cited by 369
Prenatal diagnosis of placenta previa accreta by transabdominal color Doppler ultrasound
Chou, M. M., Ho, E. S. C., & Lee, Y. H. (2000) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2000.00018.x · Cited by 284
Diagnosis and Management of Placenta Percreta: A Review
Hudon, L., Belfort, M. A., & Broome, D. R. (1998) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-199808000-00024 · Cited by 246
Hawass, N. E. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.832.9166071 · Cited by 230
Meng, X., Xie, L., & Song, W. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.05.017 · Cited by 118
Cited by
Obstetric Care Consensus No. 7: Placenta Accreta Spectrum
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002983 · Cited by 523
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Self-citationCenter of excellence for placenta accreta
Silver, R. M., Fox, K. A., Barton, J. R., Abuhamad, A. Z., Simhan, H., Huls, C. K., Belfort, M. A., & Wright, J. D. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.11.018 · Cited by 518
Self-citationSilver, R. M., & Branch, D. W. (2018) · New England Journal of Medicine · doi:10.1056/nejmcp1709324 · Cited by 511
Self-citationCahill, A. G., Beigi, R., Heine, R. P., Silver, R. M., & Wax, J. R. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.042 · Cited by 481
Self-citation
Metadata
- Authors
- Bowman, Z. S., Eller, A. G., Kennedy, A. M., Richards, D. S., Winter, T. C., Woodward, P. J., & Silver, R. M.
- Venue
- Journal of Ultrasound in Medicine
- Publisher
- Wiley
- Published
- 2014-12
- Volume
- 33
- Issue
- 12
- Pages
- 2153-2158
- ISSN
- 0278-4297 (ISSN-L)
- 1550-9613
- OpenAlex
- W2103268342
- Cited by
- 55
- References
- 9
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.