The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography
Open accessAbstract
CONTEXT: Coronary computed tomographic (CT) angiography is a noninvasive anatomic test for diagnosis of coronary stenosis that does not determine whether a stenosis causes ischemia. In contrast, fractional flow reserve (FFR) is a physiologic measure of coronary stenosis expressing the amount of coronary flow still attainable despite the presence of a stenosis, but it requires an invasive procedure. Noninvasive FFR computed from CT (FFR(CT)) is a novel method for determining the physiologic significance of coronary artery disease (CAD), but its ability to identify ischemia has not been adequately examined to date. OBJECTIVE: To assess the diagnostic performance of FFR(CT) plus CT for diagnosis of hemodynamically significant coronary stenosis. DESIGN, SETTING, AND PATIENTS: Multicenter diagnostic performance study involving 252 stable patients with suspected or known CAD from 17 centers in 5 countries who underwent CT, invasive coronary angiography (ICA), FFR, and FFR(CT) between October 2010 and October 2011. Computed tomography, ICA, FFR, and FFR(CT) were interpreted in blinded fashion by independent core laboratories. Accuracy of FFR(CT) plus CT for diagnosis of ischemia was compared with an invasive FFR reference standard. Ischemia was defined by an FFR or FFR(CT) of 0.80 or less, while anatomically obstructive CAD was defined by a stenosis of 50% or larger on CT and ICA. MAIN OUTCOME MEASURES: The primary study outcome assessed whether FFR(CT) plus CT could improve the per-patient diagnostic accuracy such that the lower boundary of the 1-sided 95% confidence interval of this estimate exceeded 70%. RESULTS: Among study participants, 137 (54.4%) had an abnormal FFR determined by ICA. On a per-patient basis, diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of FFR(CT) plus CT were 73% (95% CI, 67%-78%), 90% (95% CI, 84%-95%), 54% (95% CI, 46%-83%), 67% (95% CI, 60%-74%), and 84% (95% CI, 74%-90%), respectively. Compared with obstructive CAD diagnosed by CT alone (area under the receiver operating characteristic curve [AUC], 0.68; 95% CI, 0.62-0.74), FFR(CT) was associated with improved discrimination (AUC, 0.81; 95% CI, 0.75-0.86; P < .001). CONCLUSION: Although the study did not achieve its prespecified primary outcome goal for the level of per-patient diagnostic accuracy, use of noninvasive FFR(CT) plus CT among stable patients with suspected or known CAD was associated with improved diagnostic accuracy and discrimination vs CT alone for the diagnosis of hemodynamically significant CAD when FFR determined at the time of ICA was the reference standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Optimal Medical Therapy with or without PCI for Stable Coronary Disease
Boden, W. E., O'Rourke, R. A., Teo, K. K., Hartigan, P. M., Maron, D. J., Kostuk, W. J., Knudtson, M., Dada, M., Casperson, P., Harris, C. L., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa070829 · Cited by 4,699 · cited 1×
“These concerns stem from recent randomized trials that have identified no survival benefit for patients who undergo angiographically based coronary revascularization.(6,7) As an adjunct to ICA, fractional flow reserve (FFR) has served as a useful tool to determine the likelihood that a coronary”
BackgroundSelf-citationFractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
A Randomized Trial of Therapies for Type 2 Diabetes and Coronary Artery Disease
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0805796 · Cited by 1,939
Shaw, L. J., Berman, D. S., Maron, D. J., Mancini, G. B. J., Hayes, S. W., Hartigan, P. M., Weintraub, W. S., O’Rourke, R. A., Dada, M., Spertus, J. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.743963 · Cited by 1,605
Self-citationHachamovitch, R., Hayes, S. W., Friedman, J. D., Cohen, I., & Berman, D. S. (2003) · Circulation · doi:10.1161/01.cir.0000072790.23090.41 · Cited by 1,563
Self-citationACC/AHA/ASNC Guidelines for the Clinical Use of Cardiac Radionuclide Imaging—Executive Summary
Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., Cerqueira, M. D., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.011 · Cited by 1,303
Self-citationHendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Koo, B.-K., Erglis, A., Doh, J.-H., Daniels, D. V., Jegere, S., Kim, H.-S., Dunning, A., DeFrance, T., Lansky, A., Leipsic, J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.066 · Cited by 1,282
Self-citationPijls, N. H. J., Fearon, W. F., Tonino, P. A. L., Siebert, U., Ikeno, F., Bornschein, B., van't Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.012 · Cited by 1,158
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Virani, S. S., Newby, L. K., Arnold, S. V., Bittner, V., Brewer, L. C., Demeter, S. H., Dixon, D. L., Fearon, W. F., Hess, B., Johnson, H. M., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001168 · Cited by 1,598
Metadata
- Authors
- Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., Budoff, M. J., Cole, J. H., Jaffer, F. A., Leon, M. B., Malpeso, J., Mancini, G. B. J., Park, S.-J., Schwartz, R. S., Shaw, L. J., & Mauri, L.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2012-09-26
- Volume
- 308
- Issue
- 12
- Pages
- 1237
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2095680098
- Cited by
- 1,162
- References
- 25
- FWCI
- 69.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography. https://app.cochat.ai/papers/10.1001/2012.jama.11274
- The paper
- Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., Budoff, M. J., Cole, J. H., Jaffer, F. A., Leon, M. B., Malpeso, J., Mancini, G. B. J., Park, S.-J., Schwartz, R. S., Shaw, L. J., & Mauri, L. (2012). Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography. JAMA. https://doi.org/10.1001/2012.jama.11274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.