Cited by 1,303Cardiac Imaging and DiagnosticsMedical Imaging Techniques and ApplicationsCardiovascular Function and Risk Factors

ACC/AHA/ASNC Guidelines for the Clinical Use of Cardiac Radionuclide Imaging—Executive Summary

Open access
Klocke, Francis J, Baird, Michael G, Lorell, Beverly H, Bateman, Timothy M, Messer, Joseph V, Berman, Daniel S, O’Gara, Patrick T, Carabello, Blase A +20 more·2003·Journal of the American College of Cardiology

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2003.08.011

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Caffeine is a nonselective competitive A2A receptor antagonist and its use has been contraindicated before vasodilator MPI because it attenuates coronary hyperemia caused by adenosine and dipyridamole in a dose-dependent manner.

    “The use of caffeine, a nonselective competitive A 2A receptor antagonist, has been contraindicated before vasodilator MPI (3) because it attenuates the coronary hyperemia caused by the nonselective adenosine receptor agonists adenosine and dipyridamole in a dose-dependent manner (4).”
  • The interaction of caffeine with adenosine-induced, dipyridamole-induced, and exercise-induced MBF changes may limit correct detection of coronary artery disease and proper management, leading to recommendation to withhold caffeine for 24 h before vasodilator stress testing.

    “The interaction of caffeine with adenosine-induced, dipyridamoleinduced, and even exercise-induced MBF changes (4,6) may limit the correct detection of coronary artery disease and subsequently the proper management of the patient, leading to the general recommendation to withhold caffeine for 24 h before vasodilator stress testing (3).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., Cerqueira, M. D., St. John Sutton, M. G., DeMaria, A. N., Udelson, J. E., Kennedy, J. W., Verani, M. S., Williams, K. A., Antman, E. M., Smith, S. C., Alpert, J. S., Gregoratos, G., Anderson, J. L., Hiratzka, L. F., Faxon, D. P., Hunt, S. A., Fuster, V., Jacobs, A. K., Gibbons, R. J., & Russell, R. O.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2003-10
Volume
42
Issue
7
Pages
1318-1333
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2150815934
Cited by
1,303
References
64
Citations by year
2026: 3 · 2025: 8 · 2024: 8 · 2023: 12 · 2022: 14 · 2021: 30 · 2020: 22 · 2019: 21 · 2018: 23 · 2017: 38 · 2016: 33 · 2015: 59 · 2014: 75 · 2013: 87 · 2012: 101
FWCI
53.12
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
myocardial perfusion imaging, myocardial scintigraphy
MeSH terms
Coronary Artery Disease, Emergency Treatment, Heart Diseases, Heart Failure, Humans, Myocardial Infarction, Radionuclide Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review