The DOI matches its Crossref record.
Evaluation of Acellular Dermal Graft in Sheet (AlloDerm) and Injectable (Micronized AlloDerm) Forms for Soft Tissue Augmentation: Clinical Observations and Histological Analysis
Abstract
OBJECTIVES: To evaluate the histological and clinical properties of (1) subdermally implanted acellular dermal graft (AlloDerm) sheets vs intradermal bovine collagen and (2) subdermally or intradermally injected micronized AlloDerm vs type I bovine collagen cross-linked with glutaraldehyde (Zyplast). PATIENTS: Twenty-five adult patients testing nonallergic to bovine collagen. METHODS: (1) Stacked disks of AlloDerm were implanted subdermally behind one ear, and bovine collagen was injected intradermally behind the other. The soft tissue augmentation caused by the implants was measured by digital photography at 1, 4, and 12 weeks, and biopsy specimens of each implant type were examined at 3 months after implantation. (2) Micronized AlloDerm was injected intradermally and subdermally in 2 different locations behind one ear, and bovine collagen was injected in the same manner behind the other. The soft tissue augmentation caused by the implants was measured by digital photography at the time of implantation and at 1 and 4 weeks after implantation. All implants were examined 1 month after implantation. RESULTS: All patients tolerated both implants well. (1) AlloDerm implants retained a higher percentage of the original implant volume than Zyplast at 1 and 3 months after implantation. Histologically, AlloDerm implants were extensively invaded by host fibroblasts without any foreign body reaction. (2) Intradermally injected micronized AlloDerm implants retained a higher percentage of the original implant volume at 1 month after implantation than intradermal Zyplast. Histologically, micronized AlloDerm implants were extensively invaded by host fibroblasts without any foreign body reaction. No significant differences were noted between subdermally injected micronized AlloDerm and Zyplast. CONCLUSIONS: The macroscopic and microscopic behavior of subdermally implanted AlloDerm sheets and subdermally and intradermally injected micronized AlloDerm was compared with intradermally injected Zyplast. AlloDerm sheet volume persisted to a significantly (P < .001) greater degree than bovine collagen during the first 3 months after placement. Clinically, intradermally injected micronized AlloDerm volume persisted to a significantly (P = .01, .04, and .01, respectively) greater degree than intradermal Zyplast or subdermal micronized AlloDerm or Zyplast. Histologically, micronized AlloDerm and AlloDerm are well tolerated at 1 and 3 months, respectively. Host tissue incorporation with fibroblast in-growth and collagen deposition is seen in both materials. AlloDerm and micronized AlloDerm hold promise for use in facial soft tissue augmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Immune response to biologic scaffold materials
Badylak, S. F., & Gilbert, T. W. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.003 · Cited by 857
Photoaging: mechanisms and repair
Rabe, J. H., Mamelak, A. J., McElgunn, P. J. S., Morison, W. L., & Sauder, D. N. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2005.05.010 · Cited by 610
Readily Available Tissue-Engineered Vascular Grafts
Dahl, S. L. M., Kypson, A. P., Lawson, J. H., Blum, J. L., Strader, J. T., Li, Y., Manson, R. J., Tente, W. E., DiBernardo, L., Hensley, M. T., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001426 · Cited by 563
Quantification of DNA in Biologic Scaffold Materials
Gilbert, T. W., Freund, J. M., & Badylak, S. F. (2009) · Journal of Surgical Research · doi:10.1016/j.jss.2008.02.013 · Cited by 481
Adverse reactions to injectable soft tissue fillers
Requena, L., Requena, C., Christensen, L., Zimmermann, U. S., Kutzner, H., & Cerroni, L. (2011) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2010.02.064 · Cited by 338
Metadata
- Authors
- Sclafani, A. P., Romo, T., Jacono, A. A., McCormick, S., Cocker, R., & Parker, A.
- Venue
- Archives of Facial Plastic Surgery
- Publisher
- SAGE Publications
- Published
- 2000-04-01
- Volume
- 2
- Issue
- 2
- Pages
- 130-136
- ISSN
- 1521-2491 (ISSN-L)
- 1538-3660
- OpenAlex
- W2136979131
- Cited by
- 159
- References
- 0
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Acellular Dermal Graft in Sheet (AlloDerm) and Injectable (Micronized AlloDerm) Forms for Soft Tissue Augmentation: Clinical Observations and Histological Analysis. https://app.cochat.ai/papers/10.1001/archfaci.2.2.130
- The paper
- Sclafani, A. P., Romo, T., Jacono, A. A., McCormick, S., Cocker, R., & Parker, A. (2000). Evaluation of Acellular Dermal Graft in Sheet (AlloDerm) and Injectable (Micronized AlloDerm) Forms for Soft Tissue Augmentation: Clinical Observations and Histological Analysis. Archives of Facial Plastic Surgery. https://doi.org/10.1001/archfaci.2.2.130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.