How Often Do Office Blood Pressure Measurements Fail to Identify True Hypertension?: An Exploration of White-Coat Normotension
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The often-observed differences between ambulatory (ABP) and office blood pressure (OBP) measurements have brought attention to the problem of misdiagnoses. Although there has been much focus on white-coat hypertension (elevated OBP with normal ABP means), few studies have examined "white-coat normotension" (WCN; normal OBP with elevated ABP means). OBJECTIVES: To describe patients with WCN in terms of prevalence and quantitative differences between ABP and OBP; to identify psychological and demographic features that discriminate them from true normotensive patients; and to offer possible corrections for diagnostic limitations of OBP measurements in clinical practice. DESIGN AND METHODS: Five OBP measurements and 10- to 12-hour daytime ABP monitoring in 319 presumed healthy participants. RESULTS: Prevalence rates of WCN were 23% for systolic BP and 24% for diastolic BP. Participants with WCN were more often male, past smokers, and older and consumed more alcohol. Increasing the number of office readings and discarding the first office reading did not improve the accuracy of OBP measurements. Participants with BP of 10 mm Hg above or below the 140/90 office reading cutoff showed the lowest accuracy, with more than 50% of normotensive diagnoses being incorrect. CONCLUSIONS: Office measures of BP lack sensitivity, missing a sizable portion of individuals who have hypertensive mean ABP measurements. Subjects with WCN differ from true normotensive subjects on several demographic and lifestyle variables. Only those office readings averaging 20 points above or below the 140/90 cutoff represent safe diagnostic information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing social support: The Social Support Questionnaire.
Sarason, I. G., Levine, H. M., Basham, R. B., & Sarason, B. R. (1983) · Journal of Personality and Social Psychology · doi:10.1037//0022-3514.44.1.127 · Cited by 3,067
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Cited by
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Pickering, T. G., Davidson, K., Gerin, W., & Schwartz, J. E. (2002) · Hypertension · doi:10.1161/01.hyp.0000038733.08436.98 · Cited by 424
Pogue, V., Rahman, M., Lipkowitz, M., Toto, R., Miller, E., Faulkner, M., Rostand, S., Hiremath, L., Sika, M., Kendrick, C., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.115154 · Cited by 282
Masked hypertension: A systematic review
Bobrie, G., Clerson, P., Ménard, J., Postel-Vinay, N., Chatellier, G., & Plouin, P.-F. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fbcedf · Cited by 279
PICKERING, T. G., EGUCHI, K., & KARIO, K. (2007) · Hypertension Research · doi:10.1291/hypres.30.479 · Cited by 227
“(33) found that 23% had masked hypertension, and that they tended to be male, past smokers.”
Background
Metadata
- Authors
- Selenta, C.
- Venue
- Archives of Family Medicine
- Publisher
- CLOCKSS Archive
- Published
- 2000-06-01
- Volume
- 9
- Issue
- 6
- Pages
- 533-540
- ISSN
- 1063-3987 (ISSN-L)
- OpenAlex
- W1967199930
- Cited by
- 105
- References
- 3
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How Often Do Office Blood Pressure Measurements Fail to Identify True Hypertension?: An Exploration of White-Coat Normotension. https://app.cochat.ai/papers/10.1001/archfami.9.6.533
- The paper
- Selenta, C. (2000). How Often Do Office Blood Pressure Measurements Fail to Identify True Hypertension?: An Exploration of White-Coat Normotension. Archives of Family Medicine. https://doi.org/10.1001/archfami.9.6.533
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.