The Value of Fine-Needle Aspiration Biopsy in Patients With Nodular Thyroid Disease Divided Into Groups of Suspicion of Malignant Neoplasms on Clinical Grounds
Abstract
The accuracy of clinical diagnosis and fine-needle aspiration biopsy (FNAB) was evaluated in 169 patients surgically treated for nodular thyroid disease. Patients were divided into three groups with high, moderate, or low suspicion of malignant neoplasms on clinical grounds without previous knowledge of cytologic or histologic results. Histologic examination revealed an overall malignant neoplasm rate of 23%; the rate was 71%, 14%, and 11% for the groups with high, moderate, and low suspicion, respectively. The FNAB diagnostic interpretations of malignant and uncertain were considered positive. Overall sensitivity, specificity, and accuracy for FNAB were 92%, 71%, and 75%, respectively. Sensitivity in the high-, moderate-, and low-suspicion groups was 95%, 89%, and 88%, respectively; specificity was 88%, 72%, and 67%, respectively; and accuracy was 93%, 75%, and 69%, respectively. In our opinion, all patients in the group with high clinical suspicion need surgical treatment whatever the FNAB result; those with lower degrees of clinical suspicion and malignant or uncertain FNAB result [corrected] should also undergo surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Hegedüs, L. (2004) · New England Journal of Medicine · doi:10.1056/nejmcp031436 · Cited by 1,502
Management of a Solitary Thyroid Nodule
Desforges, J. F., & Mazzaferri, E. L. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302253280807 · Cited by 1,412
Gharib, H., Papini, E., Paschke, R., Duick, D. S., Valcavi, R., Hegedüs, L., Vitti, P., Gharib, H., Papini, E., Paschke, R., et al. (2010) · Endocrine Practice · doi:10.4158/10024.gl · Cited by 1,088
Management of Simple Nodular Goiter: Current Status and Future Perspectives
Hegedüs, L., Bonnema, S. J., & Bennedbæk, F. N. (2003) · Endocrine Reviews · doi:10.1210/er.2002-0016 · Cited by 710
Boelaert, K., Horacek, J., Holder, R. L., Watkinson, J. C., Sheppard, M. C., & Franklyn, J. A. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0527 · Cited by 534
DANESE, D., SCIACCHITANO, S., FARSETTI, A., ANDREOLI, M., & PONTECORVI, A. (1998) · Thyroid · doi:10.1089/thy.1998.8.15 · Cited by 522
Baloch, Z. W., Cibas, E. S., Clark, D. P., Layfield, L. J., Ljung, B.-M., Pitman, M. B., & Abati, A. (2008) · CytoJournal · doi:10.1186/1742-6413-5-6 · Cited by 382
Fine-Needle Aspiration Cytology of the Thyroid: A 12-Year Experience With 11,000 Biopsies
Gharib, H., Goellner, J. R., & Johnson, D. A. (1993) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30434-7 · Cited by 346
TUTTLE, R. M., LEMAR, H., & BURCH, H. B. (1998) · Thyroid · doi:10.1089/thy.1998.8.377 · Cited by 286
Metadata
- Authors
- Hamming, J. F.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association
- Published
- 1990-01-01
- Volume
- 150
- Issue
- 1
- Pages
- 113-113
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2031901280
- Cited by
- 202
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.