Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Population-Based Study of the Effectiveness of Inferior Vena Cava Filter Use Among Patients With Venous Thromboembolism

Open access
White, Richard H., Zhou, Hong, Kim, Jinwoo, Romano, Patrick S. · 2000 · Archives of Internal Medicine

Abstract

BACKGROUND: There are few population-based data regarding the effectiveness of inferior vena cava filter use in the prevention of symptomatic pulmonary embolism. OBJECTIVE: To determine the 1-year cumulative incidence of rehospitalization for venous thrombosis or pulmonary embolism among patients with thromboembolism treated with a vena cava filter compared with the incidence in a control population with thromboembolism. PATIENTS AND METHODS: Population-based retrospective analysis of linked hospital discharge abstracts in California. From January 1, 1991, through December 30, 1995, 3632 patients were treated with a filter and 64,333 controls were admitted with a principal diagnosis of venous thromboembolism. RESULTS: Filter-treated patients had significantly greater comorbidity, with a higher frequency of previous pulmonary embolism, recent major bleeding, malignant neoplasm, and stroke. Patients who initially manifested pulmonary embolism were significantly more likely to be rehospitalized for pulmonary embolism than patients with an initial diagnosis of venous thrombosis alone, among filter-treated patients (relative risk, 6.72; 95% confidence interval, 3.61-12.49) and controls (relative risk, 5.30; 95% confidence interval, 4.61-6.10). Risk-adjusted proportional hazards modeling showed no significant difference between filter-treated patients and controls in the relative hazard of rehospitalization for pulmonary embolism. However, filter placement was associated with a significantly higher relative hazard of rehospitalization for venous thrombosis among patients who initially manifested pulmonary embolism (relative hazard, 2.62; 95% confidence interval, 2.09-3.29), but not among those who presented with venous thrombosis (relative hazard, 1.14; 95% confidence interval, 0.92-1.43). CONCLUSIONS: Insertion of a vena cava filter was not associated with a significant reduction in the 1-year incidence of rehospitalization for pulmonary embolism. Use of a filter was associated with a higher incidence of rehospitalization for venous thrombosis, but only among patients who initially manifested pulmonary embolism. A prospective clinical study is needed to determine the efficacy of filter use among patients with pulmonary embolism who do not meet strict guidelines for insertion of a vena cava filter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.160.13.2033

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
White, R. H., Zhou, H., Kim, J., & Romano, P. S.
Venue
Archives of Internal Medicine
Published
2000-07-10
Volume
160
Issue
13
Pages
2033
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2103228243
Cited by
195
References
1
FWCI
6.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Population-Based Study of the Effectiveness of Inferior Vena Cava Filter Use Among Patients With Venous Thromboembolism. https://app.cochat.ai/papers/10.1001/archinte.160.13.2033
The paper
White, R. H., Zhou, H., Kim, J., & Romano, P. S. (2000). A Population-Based Study of the Effectiveness of Inferior Vena Cava Filter Use Among Patients With Venous Thromboembolism. Archives of Internal Medicine. https://doi.org/10.1001/archinte.160.13.2033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.