Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 749

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Anticoagulation of Pregnant Women With Mechanical Heart Valves: A Systematic Review of the Literature

Chan, Wee Shian, Anand, Sonia, Ginsberg, Jeffrey S.·2000·Archives of Internal Medicine

Abstract

BACKGROUND: The management of women with prosthetic heart valves during pregnancy poses a particular challenge as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants such as warfarin sodium cause fetal embryopathy; subcutaneous administration of heparin sodium has been reported to be ineffective in preventing thromboembolic complications. OBJECTIVE: To identify the risks of maternal and fetal complications in women with mechanical heart valves treated with different anticoagulation regimens during pregnancy. METHODS: We performed a systematic review of the literature to determine pooled estimates of maternal and fetal risks associated with the 3 commonly used approaches: (1) oral anticoagulants (OA) throughout pregnancy, (2) replacing OA with heparin in the first trimester (from 6-12 weeks' gestation), and (3) heparin use throughout pregnancy. Fetal outcomes included spontaneous abortions and fetopathic effects, and maternal outcomes were major bleeding, thromboembolic complications, and death. RESULTS: The use of OA throughout pregnancy is associated with warfarin embryopathy in 6.4% (95% confidence interval [CI], 4.6%-8.9%) of livebirths. The substitution of heparin at or prior to 6 weeks, and continued until 12 weeks, eliminated this risk. Overall risks for fetal wastage (spontaneous abortion, stillbirths, and neonatal deaths) were similar in women treated with OA throughout, compared with women treated with heparin in the first trimester. Maternal mortality was 2.9% (95% CI, 1.9%-4.2%). Maj or bleeding events occurred in 2.5% (95% CI, 1.7%-3.5%) of all pregnancies, most at the time of delivery. The regimen associated with the lowest risk of valve thrombosis (3.9%; 95% CI, 2.9-5.9%) was the use of OA throughout; using heparin only between 6 and 12 weeks' gestation was associated with an increased risk of valve thrombosis (9.2%; 95% CI, 5.9%-13.9%). CONCLUSIONS: Thromboembolic prophylaxis of women with mechanical heart valves during pregnancy is best achieved with OA; however, this increases the risk of fetal embryopathy. Substituting OA with heparin between 6 and 12 weeks reduces the risk of fetopathic effects, but with an increased risk of thromboembolic complications. The use of low-dose heparin is definitely inadequate; the use of adjusted-dose heparin warrants aggressive monitoring and appropriate dose adjustment. Large prospective trials to determine the best regimen for these women are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.160.2.191

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 749

Metadata

Authors
Chan, W. S., Anand, S., & Ginsberg, J. S.
Venue
Archives of Internal Medicine
Published
2000-01-24
Volume
160
Issue
2
Pages
191
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2138444098
Cited by
749
References
2
FWCI
17.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anticoagulation of Pregnant Women With Mechanical Heart Valves: A Systematic Review of the Literature. https://app.cochat.ai/papers/10.1001/archinte.160.2.191
The paper
Chan, W. S., Anand, S., & Ginsberg, J. S. (2000). Anticoagulation of Pregnant Women With Mechanical Heart Valves: A Systematic Review of the Literature. Archives of Internal Medicine. https://doi.org/10.1001/archinte.160.2.191

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.