Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Normal Serum Creatinine Concentration Is a Predictor of Cardiovascular Risk in Essential Hypertension

Schillaci, Giuseppe, Reboldi, Gianpaolo, Verdecchia, Paolo·2001·Archives of Internal Medicine

Abstract

BACKGROUND: Determination of serum creatinine concentration is recommended in all patients with hypertension as a marker of target organ damage. However, the possibility that creatinine values within the reference range might contribute to stratification of cardiovascular risk in essential hypertension has never been tested. PATIENTS AND METHODS: In the setting of the Progetto Ipertensione Umbria Monitoraggio Ambulatoriale Study, for up to 11 years (mean, 4 years) we followed up 1829 white patients with hypertension (mean +/- SD age, 51 +/- 12 years; 53% men; office blood pressure, 157/98 mm Hg) free of cardiovascular events and with normal pretreatment creatinine levels (men, <136 micromol/L [<1.5 mg/dL]; women, <120 micromol/L [<1.4 mg/dL]) who also underwent 24-hour blood pressure monitoring and electrocardiography before therapy. RESULTS: During follow-up, there were 175 fatal or nonfatal major cardiovascular morbid events (2.4 per 100 patient-years). Event rate increased progressively from the first to the fourth sex-specific quartiles of creatinine distribution (1.5, 2.3, 2.3, and 3.5 per 100 patient-years; P =.003 by log-rank test). After adjustment (in a multivariate Cox model) for age, sex, diabetes, cholesterol, smoking, left ventricular hypertrophy, and 24-hour pulse and mean blood pressures (P<.05 for all), creatinine concentration was an independent adverse predictor of cardiovascular morbid events (P =.01). The observed excess risk was 1.30 (95% confidence interval, 1.07-1.59) for a 20-micromol/L (0.23-mg/dL) increase in creatinine concentration. CONCLUSIONS: A serum creatinine value within the reference range is a predictor of cardiovascular morbidity in white patients with essential hypertension. Its prognostic value persists after adjustment for several powerful confounders, including average 24-hour blood pressure and left ventricular hypertrophy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/archinte.161.6.886

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 176

Metadata

Authors
Schillaci, G., Reboldi, G., & Verdecchia, P.
Venue
Archives of Internal Medicine
Published
2001-03-26
Volume
161
Issue
6
Pages
886
ISSN
0003-9926 (ISSN-L)
OpenAlex
W2037343844
Cited by
176
References
1
FWCI
11.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Normal Serum Creatinine Concentration Is a Predictor of Cardiovascular Risk in Essential Hypertension. https://app.cochat.ai/papers/10.1001/archinte.161.6.886
The paper
Schillaci, G., Reboldi, G., & Verdecchia, P. (2001). High-Normal Serum Creatinine Concentration Is a Predictor of Cardiovascular Risk in Essential Hypertension. Archives of Internal Medicine. https://doi.org/10.1001/archinte.161.6.886

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.