Midterm Prognosis of Patients With Suspected Coronary Artery Disease and Normal Multislice Computed Tomographic Findings: A Prospective Management Outcome Study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The gold standard test for the diagnosis of coronary artery disease (CAD) is conventional coronary angiography (C-CAG). Lately, multislice computed tomographic coronary angiography (MSCT-CAG) demonstrated a high sensitivity and a negative predictive value for a CAD primary diagnosis when compared with C-CAG. The aim of our study is to prospectively assess the safety of ruling out CAD based solely on a normal MSCT-CAG result. METHODS: From June 15, 2004, to January 20, 2006, consecutive patients initially scheduled for C-CAG for a primary diagnosis of CAD underwent MSCT-CAG instead. Patients with a highly calcified coronary network or with an abnormal or a noninterpretable MSCT-CAG result underwent secondary C-CAG and were excluded from the study. We included patients whose diagnosis of CAD was ruled out by a normal MSCT-CAG result; in those patients, C-CAG was not performed. All patients underwent further follow-up with clinical end points (death, subsequent C-CAG, and myocardial infarction). RESULTS: In 141 patients, MSCT-CAG results were considered normal. During the follow-up period (mean, 14.7 months), those patients experienced 0% mortality, a 3.5% rate of subsequent C-CAG, and a 0.7% rate of myocardial infarction. The risks of subsequent death, new referral for C-CAG, or coronary events compare favorably with those following normal C-CAG, which were 0.4%, 4.3%, and 0.6%, respectively. CONCLUSIONS: Multislice computed tomographic CAG safely rules out CAD in patients with suspected disease and allows patients to be managed less invasively, by reducing the number in whom C-CAG has to be performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 2×
“Before iodinated contrast agent injection, a native scan was performed to assess coronary calcification, using a scoring method analogous to that of Agatston et al.8 A calcified lesion was defined as an area of 3 connected pixels or greater ( 130 Hounsfield units), expressed as an Agatston score equivalent (ASE).”
Method
Cited by
Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
Meijboom, W. B., Meijs, M. F. L., Schuijf, J. D., Cramer, M. J., Mollet, N. R., van Mieghem, C. A. G., Nieman, K., van Werkhoven, J. M., Pundziute, G., Weustink, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.058 · Cited by 1,239
Comprehensive Assessment of Coronary Artery Stenoses
Meijboom, W. B., Van Mieghem, C. A. G., van Pelt, N., Weustink, A., Pugliese, F., Mollet, N. R., Boersma, E., Regar, E., van Geuns, R. J., de Jaegere, P. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.024 · Cited by 637
Prognostic Value of Cardiac Computed Tomography Angiography
Hulten, E. A., Carbonaro, S., Petrillo, S. P., Mitchell, J. D., & Villines, T. C. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.011 · Cited by 412
Ostrom, M. P., Gopal, A., Ahmadi, N., Nasir, K., Yang, E., Kakadiaris, I., Flores, F., Mao, S. S., & Budoff, M. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.027 · Cited by 366
van Werkhoven, J. M., Schuijf, J. D., Gaemperli, O., Jukema, J. W., Boersma, E., Wijns, W., Stolzmann, P., Alkadhi, H., Valenta, I., Stokkel, M. P. M., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.043 · Cited by 336
Hadamitzky, M., Freißmuth, B., Meyer, T., Hein, F., Kastrati, A., Martinoff, S., Schömig, A., & Hausleiter, J. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.11.015 · Cited by 280
Prognostic Value of 64-Slice Cardiac Computed Tomography
Chow, B. J. W., Wells, G. A., Chen, L., Yam, Y., Galiwango, P., Abraham, A., Sheth, T., Dennie, C., Beanlands, R. S., & Ruddy, T. D. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.039 · Cited by 270
Chow, B. J. W., Small, G., Yam, Y., Chen, L., Achenbach, S., Al-Mallah, M., Berman, D. S., Budoff, M. J., Cademartiri, F., Callister, T. Q., et al. (2011) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.964155 · Cited by 222
Patient Management After Noninvasive Cardiac Imaging
Hachamovitch, R., Nutter, B., Hlatky, M. A., Shaw, L. J., Ridner, M. L., Dorbala, S., Beanlands, R. S. B., Chow, B. J. W., Branscomb, E., Chareonthaitawee, P., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.066 · Cited by 199
Bamberg, F., Sommer, W. H., Hoffmann, V., Achenbach, S., Nikolaou, K., Conen, D., Reiser, M. F., Hoffmann, U., & Becker, C. R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.043 · Cited by 173
“Six studies id not provide any hazard ratio (HR) of interest (merely rovided raw data and described the occurrence of events on case basis) (3,4), included 100 subjects (5), included a uplicate publication with a different focus of the analysis 6,7), reported on costs (8), or exclusively reported on oncalcified plaque…”
Backgroundvan Werkhoven, J. M., Schuijf, J. D., Gaemperli, O., Jukema, J. W., Kroft, L. J., Boersma, E., Pazhenkottil, A., Valenta, I., Pundziute, G., de Roos, A., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp272 · Cited by 159
van Werkhoven, J. M., Gaemperli, O., Schuijf, J. D., Jukema, J. W., Kroft, L. J., Leschka, S., Alkadhi, H., Valenta, I., Pundziute, G., de Roos, A., et al. (2009) · Heart · doi:10.1136/hrt.2009.167353 · Cited by 52
Metadata
- Authors
- Gilard, M.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2007-08-13
- Volume
- 167
- Issue
- 15
- Pages
- 1686
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W1967648424
- Cited by
- 106
- References
- 1
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.