Use of a Sensitive Thyrotropin Assay for Monitoring Treatment With Levothyroxine
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To determine if a sensitive assay for thyrotropin (thyroid-stimulating hormone [TSH] ) would be useful as a primary test to determine optimal doses of levothyroxine, an enzyme immunoassay for TSH that discriminated hyperthyroid from euthyroid subjects with no overlap was compared with radioimmunoassays for TSH and thyroxine (T4) and the calculated free thyroxine index (FTI) in 100 patients receiving stable doses of levothyroxine. The basal TSH level, determined with the sensitive assay, predicted the TSH response to thyrotropin-releasing hormone (TRH); all patients whose basal TSH level was less than 0.35 mU/L had absent or subnormal responses, and all patients with TSH levels of 0.35 mU/L or greater had normal responses. In patients with normal TSH levels, the T4 level and FTI were superfluous (normal) or misleadingly high; conversely, 65% of patients with low TSH levels had normal T4 levels or FTIs, or both. An assay for TSH with sufficient sensitivity to discriminate between abnormally low values and the low range of normal can be used as the primary test for monitoring levothyroxine treatment. The T4 or FTI measurements are not needed if the TSH level is normal, but they should be done in patients with low TSH levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Alterations in thyroid function in patients with systemic illness: the euthyroid sick syndrome
WARTOFSKY, L., & BURMAN, K. D. (1982) · Endocrine Reviews · doi:10.1210/edrv-3-2-164 · Cited by 916
Thyroid-Pituitary Interaction: Feedback Regulation of Thyrotropin Secretion by Thyroid Hormones
Bleich, H. L., Moore, M. J., & Larsen, P. R. (1982) · New England Journal of Medicine · doi:10.1056/nejm198201073060107 · Cited by 357
Fish, L. H., Schwartz, H. L., Cavanaugh, J., Steffes, M. W., Bantle, J. P., & Oppenheimer, J. H. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703263161302 · Cited by 353
Davis, F. B. (1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350210064009 · Cited by 64
New Sensitive lmmunoradiometric Assays for Thyrotropin
ROSS, D. S. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-104-5-718 · Cited by 27
Cited by
Applications of a New Chemiluminometric Thyrotropin Assay to Subnormal Measurement*
SPENCER, C. A., LoPRESTI, J. S., PATEL, A., GUTTLER, R. B., EIGEN, A., SHEN, D., GRAY, D., & NICOLOFF, J. T. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-70-2-453 · Cited by 371
ROSS, D. S., DANIELS, G. H., & GOUVEIA, D. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-71-3-764 · Cited by 126
Monitoring Therapy in Patients Taking Levothyroxine
Helfand, M., & Crapo, L. M. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-6-450 · Cited by 62
Escalante, D. A., Arem, N., & Arem, R. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80316-7 · Cited by 29
Metadata
- Authors
- Watts, N. B.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 1989-02-01
- Volume
- 149
- Issue
- 2
- Pages
- 309
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W2035510928
- Cited by
- 16
- References
- 5
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.